FUSION SPLICER 90S Rev5
35
4.
Close and gently push down on the Lever until it stops. The blade
automatically moves and cleaves the fiber.
Lift the Lever until it stops and remove the fiber from the cleaver. Be careful
not to allow the fiber to contact anything, as this can contaminate the end-
face of the fiber.
Fiber Cleaving when using a Fiber Holder
Install the Fiber holder set Plate (SP-03)
1.
Loosen the 3 screws and remove each sheath clamp from the fusion
splicer.
2.
Attach the Fiber holder set plate (SP-03) on the base and tighten 3 screws.
3.
Set the fiber onto the fiber holder and close the lid of the fiber holder.
Methods of setting the fiber are as follows.
Do not put fingers in the cleaving area as personal injury may
result.
Push the center of lever to
cleave.
Loosen 3 screws