8-18
8.2 Scanner Section
Removal
1. Install the fixing bracket to conjugate length
variable section
.
2. Remove the three screws and then the lens
section lower cover.
3. Disconnect the M202 connector.
4. Remove the connector from the bracket and cut
the cord tie.
5. Cut the cord tie.
6. Remove the two screws and then the lens drive
motor.
Installation
Installation is essentially in the reverse order of
removal.
After installation, perform the following adjustments.
1) Menu 0346 “Optical Magnification Calibration”
2) Menu 0347 “Focus Calibration”
3) Menu 0321 “Focus Position Adjustment”
8.2.12
Lens Drive Motor (M202) Replacement
Z
2
145
Screws (3)
Lens Section
Lower Cover
Z
2
146
M202 Connector
Connector
Cord Tie
Z
2
147
Screws (2)
Lens Drive Motor (M202)
Cord Tie