7-96
7.6 Carrier Base Section
Removal
1. Remove the carrier lock assembly
2. Cut the three cord ties.
3. Remove the screw and then the retainer plate.
4. Remove the screw and then the sensor.
Installation
Installation is essentially in the reverse order of
removal.
NOTE: Tighten the two screws for the retainer plate and
sensor while pressing the sensor against the pin so
that it is ON.
Removal
1. Remove the scanner lower cover
.
2. Loosen the screw and open the CTB23 circuit
board bracket.
3. Disconnect the D208 connector.
7.6.3
Carrier Lock Sensor (D208) Replacement
Z
2
184
Retainer Plate
Cord Ties (3)
Screw
Screw
Sensor (D208)
Pin
7.6.4
Carrier Lock Assembly Removal/Reinstallation
Z
2
020
CTB23 Circuit Board Bracket
Screw
Z
2
183
D208
Connector