1. Check the area of your repair for unsoldered or

poorly soldered connections. Check the entire board
surface for solder splasher and bridges.

2. Check the interboard wiring to ensure that no wires

are “pinched” or contact high-wattage resistors.

3. Look for unauthorized replacement parts, particu-

larly transistors, that were installed during a previ-
ous repair. Point them out to the customer and rec-
ommend their replacement.

4. Look for parts which, though functioning, show ob-

vious signs of deterioration. Point them out to the
customer and recommend their replacement.

5.

Caution:
For continued protection against
fire hazard, replace only with same
type 2.5 amperes 125/250 volts
fuse.
Attention:
Afin d’assurer une protection
permanente contre les risques
d’incendie, remplacer uniquement
par un fusible de meme, type 2.5
amperes, 125/250 volts.

6.

Warning:
To reduce the electric shock, be
careful to touch the parts.

  SAFETY CHECK-OUT

After correcting the original problem, perform the following
safety check before return the product to the costomer.

WARNING!

HIGH VOLTAGE

RISK OF FIRE-
REPLACE FUSE
AS MARKED

2.5A 125/250V

2.5A 125/250V

Summary of Contents for FinePix6900Zoom

Page 1: ...0Zoom TROUBLESHOOTING GUIDE U E EG Model Ref No ZM00369 400 Printed in Japan 2001 11 NT WARNING THE COMPONENTS INDENTIFIED BY MARK IN THE PARTS LIST SHOULD BE REPLACED ONLT BY THE COMPONENTS SPECIFIED IN THE PARTS LIST RISK OF FIRE AND ELECTRIC SHOCK ...

Page 2: ...hich though functioning show ob vious signs of deterioration Point them out to the customer and recommend their replacement 5 Caution For continued protection against fire hazard replace only with same type 2 5 amperes 125 250 volts fuse Attention Afin d assurer une protection permanente contre les risques d incendie remplacer uniquement par un fusible de meme type 2 5 amperes 125 250 volts 6 Warn...

Page 3: ...FinePix6900Zoom TROUBLESHOOTING GUIDE 3 Contents Page 1 POWER 4 2 LENS 5 3 AUTO FOCUS 5 4 IMAGE 5 5 CARD CONNECTOR 6 6 LCD 6 7 OPERATION 7 ...

Page 4: ...s for the position where each parts is mounted Cause 2 The open fuse line on DCST PWB ASSY was generated by the reverse mounting the capacitor on MAIN PWB ASSY Repair work MAIN PWB ASSY Replace of C110 DCST PWB ASSY Replace of F504 Refer to the schematics for the position where each parts is mounted Cause 3 The open fuse line and the transistor short circuit were generated by the capacitor short c...

Page 5: ... Cause There is no influence in the taking a picture image There was dust it to was possible to confirm in the lens Repair work The replace of LENS CONST according to the user specification Problem The lens does not return to the home position Cause Defect by user responsibility fall shock Repair work Replace of LENS CONST 3 AUTO FOCUS Problem Focus error Cause The focus error was caused because o...

Page 6: ... or less Black spot 9 pieces or less Repair work The replace of LCD according to the user specification though it is a product standard 5 CARD CONNECTOR Problem SSFDC cannot read Card error Cause The card connector solder is defective on MAIN PWB ASSY Repair work MAIN PWB ASSY Resolder of CN302 Refer to the schematics for the position where parts are mounted ...

Page 7: ... permission Operation is defective of the Self timer Continuous shooting Macro Flash AE lock Focus check button Cause Defective operation was generated by the dirt of the FFC contacted part of the mode assy Repair work Replace of mode assy Clean the FFC point of contact to prevent the re breakdown at the replace of the mode assy Do not touch the FFC point of contact when you mount the mode assy ...

Page 8: ...26 30 Nishiazabu 2 chome Minato ku Tokyo 106 8620 Japan FUJI PHOTO FILM CO LTD ...

Reviews: