FCR PRIMA T2 Operation Manual 897N102546
Page 1: ...tion Manual thoroughly before actually operating the FCR PRIMA T2 CR IR 392 system After reading this manual store it nearby the FCR PRIMA T2 CR IR 392 so that you can see it whenever necessary CR IR...
Page 2: ...ii FCR PRIMA T2 Operation Manual 897N102546...
Page 3: ...an those speci ed by FUJIFILM Corporation 6 FUJIFILM Corporation shall not be liable for malfunctions and damages resulting from negligence of precautions and operating methods contained in this manua...
Page 4: ...392 Main Unit 2 2 2 2 2 Operation Panel 2 3 2 2 3 Operation Panel Display at the Time of Startup Shutdown 2 4 Chapter 3 Basic Operation 3 1 Performing Erasure Before Use IPs 3 1 3 2 System Startup Sh...
Page 5: ...rate this equipment be sure to observe those precautions Failure to do so may cause you to subject to injuries or property damage to occur This system is classified as a medical device under EC Direct...
Page 6: ...s functioning properly 3 2 Confirm that the ground wire has been completely connected 3 3 Make sure that all cords have been connected properly and safely 3 4 Be aware that correct diagnosis can be hi...
Page 7: ...pect there is a malfunction CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Authorized Safety Standards...
Page 8: ...electrical shock Install the equipment where no water may subject the equipment Ensure that the equipment is properly grounded Check that all the cables are properly and perfectly connected When using...
Page 9: ...Connect the equipment into an outlet on a circuit different from that to which the other device s are connected Consult the manufacturer or field service technician for help Further information for I...
Page 10: ...air 2 kV contact 4 kV contact 6 kV contact 2 kV air 4 kV air 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at le...
Page 11: ...stance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occu...
Page 12: ...tput power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 80 MHz to 800 MHz d 1 2 800 MHz to 2 5 GHz d 2 3 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73...
Page 13: ...means of the patient s full name birthdate and the like 10 Before inserting a cassette into the FCR PRIMA T2 CR IR 392 be sure to read the exposure menu 11 Before inserting a cassette into the FCR PR...
Page 14: ...official dealer or local presentative provided Caution Label 2 Do not connect telephone lines to LAN connector Only the IEC 60950 1 EN 60950 1 standard non shielded cables are appropriate for connecti...
Page 15: ...Label 2 Do not connect telephone lines to LAN connector Only the IEC 60950 1 EN 60950 1 standard non shielded cables are appropriate for connection to this connector Caution Label 3 Use this terminal...
Page 16: ...e disposed of with your household waste according to the WEEE Directive 2002 96 EC and your national law This product should be handed over to a designated collection point Improper handling of this t...
Page 17: ...e processing the system produces radiographs that have a high diagnostic value and are easy to interpret 2 The system has a wide latitude for incident X rays so that a large amount of X ray diagnostic...
Page 18: ...cassette that contains an exposed IP Main Power Switch Leave it turned ON ON I Main Power ON OFF O Main Power OFF Power Inlet Power inlet for this equipment External Device Connector I F Cable Used f...
Page 19: ...ejecting the processed cassette Lights off when you remove the cassette When this lamp is on alternately with the Cassette Ready Lamp an unprocessed cassette is ejected When this lamp is on alternatel...
Page 20: ...n completed Study by Console started cassette insertion possible ON Display status when the stand by switch is set to ON Status Power Erasing Mode Indicator Lamp Status Display LED Excessive amount of...
Page 21: ...e degradation may result Precautions to observe before using an IP or when deleting images from an over exposed IP See Z 1 2 Precautions to Observe Before Using an IP in the Reference Guide By using t...
Page 22: ...2 s operation panel is on If the power erasing mode indicator lamp is not lit turn ON the main power switch Power Erasing Mode Indicator Lamp Console unconnected Status when initialization has been co...
Page 23: ...Cassette Removal Lamp should be blinking 2 On a screen from which the console can be shut down select 3 The following dialog appears Confirm that the Shutdown the PC is selected and press OK The syste...
Page 24: ...dy Lamp is lit green on the operation panel Cassette Ready Lamp 2 Insert a cassette into the equipment in alignment with the guide on the right with the cassette s barcode window facing as illustrated...
Page 25: ...tch on the operation panel to turn the power ON Stand by Switch The FCR PRIMA T2 starts initialization operation When the FCR PRIMA T2 is up and running the cassette ready lamp lights on the operation...
Page 26: ...by Switch on the operation panel for four seconds Stand by Switch The status display LED changes from off line to shutdown processing When FCR PRIMA T2 shuts down the status display LED goes out See...
Page 27: ...normally with the FCR PRIMA T2 For daily care clean the cassette set unit everyday Use the Users Checksheet when performing daily checks and maintenance Enter the following items of information into...
Page 28: ...e equipment constantly Make a copy when you are using this check sheet Verification Details Frequency Date of verification Does the equipment start up normally Daily Is the communication possible norm...
Page 29: ...n a process count of about 12 000 is reached Three years or when a process count of about 18 000 is reached Four years when a process count of about 24 000 is reached Five years when a process count o...
Page 30: ...r years or when a process count of about 24 000 is reached Perform the preventive maintenance shown below Cleaning of the parts Suction cups rubber rollers Reflection plate and filter of the erasure u...
Page 31: ...ng conditions Temperature 15 C 40 RH 30 C 80 RH Humidity 15 RH 30 C 80 RH 30 C no dew condensation Atmospheric pressure 750 hPa 1060 hPa 2 Non operating conditions Temperature 0 C 45 C no freeze conde...
Page 32: ...A 2 Appendix A Specifications FCR PRIMA T2 Operation Manual 897N102546...
Page 33: ...Operation Manual 897N102546 Maintenance and Inspection 1 Maintenance and Inspection Items Assigned to Specified Dealer For periodical inspection of the equipment and necessary arrangements consult our...