- 11 -
Indoor Unit
Indica on
PCB Indicator
Message
Solu on
Show
【
E1
】
Flash Once
Wrong Signal
Check if the co
cord
between main control board and
driving board
Show
【
E2
】
Flash Twice
Error happens on the voltage
Check the voltage and the DC high
tension cord DBL, DBN, DCN1, DCP1
and DCP2 on driving board.
Show
【
E3
】
Flash Three Times
Discharge tube of compressor
is over heat
Check outdoor unit and see if there
are following errors happen.
- poor heat dissipa on
- refrigerant pressure
- cooling fan breakdown
- poor ven l on
Show
【
E4
】
Flash Four Times
IPM is out of order
Check the ground wire if it displays
E4 when compressor operate a
while.
Check driving board and see if the
IPM has been locked.
Check driving board and wiring U, V
and W if it displays E4 when
compressor starts.
Show
【
E7
】
Flash Seven Times
Error happens on discharge
tube
Check the sensor co
CN35
or replace sensor.
Show
【
E8
】
Flash Eight Times
Error happens on Heat Sink
Sensor of IPM
Check refrigerant pressure and
pipeline leakages.
Show
【
E9
】
Flash Nine Times
Error happens on the
opera
of the compressor
Check the ground wire if it displays
E9 When compressor operate a
while.
Check the wiring U, V and W on
driving board if it displays E9 while
compressor starts.
Show
【
EA
】
Indoor temperature sensor is
out of order.
Check the sensor co
CN31
or replace sensor.
Show
【
Eb
】
Check the sensor co
CN32
or replace sensor.
Show
【
EC
】
Outdoor temperature sensor
is out of order
Check the sensor co
CN33
or replace sensor.
The sensor of evaporator is
out of order.
Show
【
EE
】
Discharge tube is out of order
Check the sensor connection CN35
or replace sensor.