Fuji Electric RMA-C1 Series Installation Manual Download Page 2

Rail Mounting Base Models 

Applicable Inverter Models 

FRN002C1S-2U 
FRN003C1S-2U 

FRNF50C1S-4U 
FRN001C1S-4U 
FRN002C1S-4U 
FRN003C1S-4U

 

FRN002C1S-7U 

FRN001C1S-6U 

RMA-C1-2.2 

FRN001C1E-7U 

FRN005C1S-2U 

FRN005C1S-4U 

FRN003C1S-7U 

RMA-C1-3.7 

3. Precautions on Usage

(1)  In an environment where the FRENIC-Mini may be subjected to vibration or impact, the FRENIC-Mini installed to a din rail is 

NOT

 recommended. 

(2)  Installation of the FRENIC-Mini with a rail mounting base is allowed only when the FRENIC-Mini is installed vertically. 

(3)  When installing the FRENIC-Mini series of inverters together with other devices on the same din rail, keep a space of at least 10 

mm(0.4 in) between components. However, as long as you are installing the FRENIC-Mini series of inverters only and the ambient 
temperature is 40ºC(104ºF) or below, side-by-side installation of the inverter without a gap is possible. 

4. Installation Procedure

(1) Installing 

rail

Secure a din rail (on which you want to set up your 
FRENIC-Mini) with mounting screws at intervals of 
a maximum of 200 mm(8 in) 100 mm(4 in) or less 
recommended). 

Max. 200 mm(8 in)

Max. 200 mm(8 in)

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Summary of Contents for RMA-C1 Series

Page 1: ...erter 4 If the rail mounting base is model RMA C1 2 2 or RMA C1 3 7 four screws M4x12 are also contained in the package If you suspect the product is not working properly or if you have any questions about the product contact the shop where you bought the product or your local FUJI branch office RMA C1 0 75 RMA C1 2 2 RMA C1 3 7 Nameplate Nameplate 2 Rail Mounting Base Models and Applicable Invert...

Page 2: ...i is installed vertically 3 When installing the FRENIC Mini series of inverters together with other devices on the same din rail keep a space of at least 10 mm 0 4 in between components However as long as you are installing the FRENIC Mini series of inverters only and the ambient temperature is 40ºC 104ºF or below side by side installation of the inverter without a gap is possible 4 Installation P...

Page 3: ...ng the rail mounting base with the FRENIC Mini to the din rail 1 Hook the upper latches of the rail mounting base over the upper edge of the din rail 2 Press the lower end of the FRENIC Mini against the din rail until the lower latches of the rail mounting base catch the din rail Figure 2 Removing the rail mounting base with the FRENIC Mini from the din rail 1 While holding the FRENIC Mini by hand...

Page 4: ...ss the lower end of the FRENIC Mini against the din rail until the lower latches of the rail mounting base catch the din rail Removing the rail mounting base with the FRENIC Mini from the din rail See Figure 3 1 While holding the FRENIC Mini by hand pull down the handle of the rail mounting base and pull the lower end of the FRENIC Mini towards you to release it from the lower latches of the din r...

Reviews: