3.4.7 Tools
PRG > 6
3.4.7.1 Monitor Customizable Logic: “CLogic Monitor”
PRG > 6 > 1
Customizable logic can be previewed graphically in each function block.
Figure 3.19 Customizable logic monitor (display example)
3.4.7.2 Load Factor Measurement: “Load Factor”
PRG > 6 > 2
This function enables measurement of the maximum output current, average output current and average
braking power. Measurement modes are indicated in the table below.
Measurement Mode
Details
Mode for measuring for a fixed period of
time
Mode for setting a measurement period and taking measurements for
a set period of time
Mode for measuring from run to stop
Mode for taking measurements from the beginning to the end of a run
If in the mode to measure the interval from run to stop, entering this mode while running will
take measurements during the period until stopping. If entering this mode while stopped,
measurements will be taken from the next run until the stop.
During load factor measurement, the key transitions into running mode. The key
moves to the measurement mode selection screen. In this case, load factor measurement will
be continued.
3.4.7.3 Communication Debug: “COM Debug”
PRG > 6 > 3
Communication-specific function codes (S, M, W, W1, W2, W3, X, Z) can be monitored and set.
REM
Clogic Monitor
PRG>6>1[1/200]
S.Spd
1450
r/min
MAX: +100
Step001:2003
S003
-15.0
12.0
-1.25
MIN: -99.9
[12]
Block function image
Output value
Input value
Ancillary information
In this case, these show
minimum/maximum limiter.
Step #
and
block function #
signal name
and
Input type
Digital signal
Analog signal
3-29