INVERTER SIO Driver
GP-Pro EX Device/PLC Connection Manual
32
Device Setting
To display the setting screen, touch [Device/PLC Settings] from [Peripheral Equipment Settings]. Touch the
External Device you want to set from the displayed list, and touch [Device Settings].
Timeout
Enter the time (seconds) for which the Display waits for the response from the External
Device, from "1 to 127".
• If the Timeout value is set to less than 10(s), it will be changed to 10(s) when initializing
the External Device from the Display. After initialization, it will return to the original set
value.
Retry
In case of no response from the External Device, use an integer from 0 to 255 to enter how
many times the Display retransmits the command.
Wait To Send
Enter the standby time (milliseconds) from when the Display receives packets until it
transmits the next command, from "0 to 255".
Setup Items
Setup Description
Device/PLC Name
Select the External Device to set as a device. Device/PLC name is the title of the External
Device set with GP-Pro EX.((Initial value [PLC1])
Series
Displays the series of the External Device.
Station Address
Enter the station address of the External Device, using 1 to 31.
Setup Items
Setup Description