The installation environment for the inverter in which this product is being installed is listed Table 3-1-1   

Table 3-1-1  Installation Environment. 

Item  

Specifications 

Remarks 

Location Indoors  - 

Ambient 

temperature 

-10  to  50

°

C - 

Ambient relative 

humidity 

5  to 95% 

Environment 

The place should  be away from direct sunlight and free from dust, corrosive gases, 

inflammable gases, oil mists, steam, dripping water or vibration. Salty  environments 

should preferably be avoided. Avoid places where sudden changes in temperature occur 

which could cause condensation or freezing. 

Altitude 

Up to 1000m 

 

 

 

Please set    up so that power terminal may become the lower side.Please set up vertically on a strong building with the 

bolt.Please do not turn upside down and do not set up in a horizontal plane.   

This option generates heat, and install space more than each of 100 

  the top and bottom and the right and left to 

secure the passage of the cooling style, please.The generated heat is radiated up. Please do not install    under a weak 

equipment to heat.Moreover, installation respect must use the one of the material that the temperature rise can be 

endured enough.   

Please consider enough to ventilation so that the ambient temperature of the inverter and the braking resistor should 

not exceed the specification value when storing in the control board etc.Please do not store in a small sealing up box 

where heat radiation is bad.   

 

WARNING

 

 

The surface temperature of resistance becomes 400

  or less by the use state.   

There is risk of fire or burn.

 

 

Please install    in a nonflammable thing such as the metals. 

There is risk of fire. 

 

Please do not arrange the combustible in surroundings. 

There is risk of fire. 

 

3-2  Installation method 

3-1  Installation Environment

3  Installation

 

 

4

 

 

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Summary of Contents for DB C Series

Page 1: ...device or control board and shipped make sure that the actual end user of the inverter receives this manual gThe contents of this manual are subject to changes for improvement without notice Fuji Ele...

Page 2: ...or similar instrument to check the voltage before performing installation or wiring Check whether the charge lamp goes off as electric shock may occur Discharge statistic electricity from your body be...

Page 3: ...irm the form with the ratings signature board 1 2 Outlines Fig 1 Fig 2 2 Table 1 2 1 Outlines Fig 3 Fig 4 Si ze M odel Fi g W W 1 H H1 D DB0 75 2C 4C 1 43 221 215 30 5 DB2 2 2C 4C 2 67 188 172 55 DB3...

Page 4: ...medicine internally and besides wrap item procedure when the influence of moisture is large 2 Product guidance 2 1 Product Warranty This product is guaranteed against defects in workmanship for 18 mo...

Page 5: ...nstall space more than each of 100 the top and bottom and the right and left to secure the passage of the cooling style please The generated heat is radiated up Please do not install under a weak equi...

Page 6: ...5 or more Note 2 The wiring length is assumed to be 5m or less Recommended connection method Terminal for braking resistor connection Table 3 3 2 Type Terminal form Connection method DB0 75 2C DB0 75...

Page 7: ...t with either of inverter side control terminal X1 X9 for the G11 series At this time please set the connected terminal function data in 9 among function codes E01 E09 Inverter Braking Resistor DB Not...

Page 8: ...uous braking time sec 90 45 45 45 30 20 15 10 15 10 7 10 7 10 7 10 10 7 Braking unit required NO Yes For 400V series Model No DB0 75 4C DB2 2 4C DB3 7 4C DB5 5 4C DB7 5 4C DB11 4C DB15 4C DB22 4C FRN0...

Page 9: ...en Electric thermal O L relay setting for braking resistor 1 5 7 5G11S 2 4 5 5 11P11S 2 4 8 D uty cycle ED As follow s T T 100sec 100 1 0 Braking power Braking time T1 Braking interval T0 Time 100 Buy...

Page 10: ...once Surface temperature of resistance by use rate The surface temperature is 230 or less 50 in surroundings temperature time I will describe the surface temperature rise value by the use rate of DB2...

Page 11: ...10 Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Reviews: