![Fuji Electric CG-UFFD Service Manual Download Page 62](http://html1.mh-extra.com/html/fuji-electric/cg-uffd/cg-uffd_service-manual_2341702062.webp)
EEPROM access error
Serial communication error between
Outdoor Unit and branch box
Serial communication error between
Indoor Unit A and branch box
Serial communication error between
Indoor Unit B and branch box
Serial communication error between
Indoor Unit C and branch box
Remote control communication error
Serial communication error between
branch boxes
Serial communication error between
branch boxes
Model information error
Indoor Unit A, liquid pipe thermistor error
(CN309)
Indoor Unit A, gas pipe thermistor error
(CN309)
Indoor Unit A, expansion valve full closure
operation error (CN305)
Indoor Unit B, expansion valve full closure
operation error (CN306)
Indoor Unit C, expansion valve full closure
operation error (CN307)
Indoor Unit B, liquid pipe thermistor error
(CN309)
Indoor Unit B, gas pipe thermistor error
(CN309)
Indoor Unit C, liquid pipe thermistor error
(CN310)
Indoor Unit C, gas pipe thermistor error
(CN310)
Power supply frequency error
Combination error
60
2010.10.29
BRANCH BOX
UTP-PY03A
Branch box
identifying
display
Primary
unit
: (1)
Secondary
unit1
: (2)
Secondary
unit2
: (3)
When an error occurs, an error description
displays in the LED (No.401 - 405).
Lit
Flashing (number of flashing)
Unlit
(n)
Comment
Green
Red
LED401
LED402
LED403
LED404
LED405
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)