background image

Enabling DC powered operation

Open  the  battery  compartment  located 

underneath the refueling station by sliding 

the cover according to the arrow.

Connect  the  refueling  station’s  output 

valve  to  the  car’s  input  valve  turning 

clockwise  while  gently  pressing  in. 

Make sure the switch beneath the car's 

chassis is at the "off" position. 

Creating renewable hydrogen 

solar power

AA B

ATTE

RY

AA B

ATTE

RY

Distilled water

Slowly  pour  water  into  the  water  tank 

opening above the refueling station until the 

water level reaches the top. Let the water 

rest in the tank for at least 5 minutes before 

moving on to the next step. This allows the 

electrolyzer time to absorb the water.

TIP: For optimal 

operation and 

longer life of the 

refueling station, 

use of distilled 

water is highly 

recommended. 

You can 

purchase distilled 

water from your 

local drugstore or 

pharmacy.

 

DC

off

Switch the refueling station to the 

"☼"

 sign. 

The small blue lights will now be flashing and 

you are now producing  hydrogen  fuel using 

unlimited  power  from  the  sun! You  can  see 

you  are  producing  hydrogen  when  small 

oxygen bubbles form on the right side of the 

water  tank.  Turn  the  switch  off  and  the 

hydrogen production will stop. 

To  purge  the  complete  fuel  cell  power 

system,  remove  all  the  air  out  of  the 

balloon by pulling on the syringe. Stop 

pulling on the syringe once all the air is 

removed from the balloon. 

Refueling and operation

Push all the air out of the syringe. Insert 

the gas purging syringe into the car’s input 

valve turning the syringe’s connector valve 

clockwise while gently pressing in.

Tips: 

1. Use the first tank of hydrogen to purge out impure gas

-- Fill the hydrogen tank and press the purging valve to 

release hydrogen completely.

2. Use the second tank of hydrogen to warm up the fuel cell

-- Re-fill the hydrogen tank and warm up the fuel cell with 

this 2nd tank of hydrogen until the balloon is empty. 

3. Run the car with the 3rd tank of Hydrogen

-- Re-fill the hydrogen tank and it’s time to run the car. 

Enjoy!

Attach the back of the solar panel to its small rectangular 

support  provided  in  the  kit.  You  can  decide  to  place  the 

solar panel vertically or horizontally depending on how you 

position the support on the back of the panel. Connect the 

black cable to the black input jack on the solar cell, and the 

red cable to the red input jack on the solar cell.

Connect the other end of the cable to the input jack of the 

refueling station. 

Place the solar panel in direct sunlight.

WARNING: Make sure these connections are 

correct. If connected incorrectly the refueling 

station may not function properly.

If  it  is  getting  dark,  or  if 

the  sun  is  not  very 

powerful, or if you want to 

accelerate refueling time, 

you  can  at  any  time 

switch 

the 

refueling 

station  to  "DC".  In  this 

case  hydrogen  would  be 

produced 

using 

the 

power of two AA alkaline 

batteries (step 7).

Disconnect  the  syringe  connector  valve  from  the 

additional input valve attached to the refueling station 

by turning it counterclockwise, allowing the connector 

to  pop  out.  Your  storage  tank  is  now  purged  and 

ready to receive hydrogen from the refueling station.

TIP: After 20 minutes of continuous use, turn the Hydrogen 

Station off, and let it rest for at least 10 minutes before 

starting it again.

Using  the  solar  panel,  make  sure  it  is  placed  in 

direct sunlight. It will take about 10 minutes in strong 

sunlight  for  the  car's  tank  to  fill  up  with  hydrogen 

using the standard solar panel included. Keep the 

refueling station powered until the balloon inside the 

hydrogen storage cylinder is full. Once the operation 

is complete and the balloon is full, make sure you 

turn the refueling station to the "off" position.

Alternative: It will take at least 1 minute for the 

balloon to fill with hydrogen using the "DC" 

power switch if the batteries are new.

WARNING: Continuous operation 

of the Hydrogen Station could 

damage it permanently.

Remote control

Step 1:

 Use the screwdriver to open the 

cover of the battery compartment.

Step 2:

 Insert 3 new LR44 batteries with 

the correct polarity positions.

Step 3:

 Use the screwdriver to close the 

cover of the battery compartment.

Activation of fuel cell 

and operation

Press  the  buttons  on 

the  remote  control  to 

control  forward  and 

backward  motions  of 

the car. Press the right 

button to keep the car 

moving forward. Press 

the  button  located  in 

the middle to keep the 

car moving backward. 

The car can turn when 

it moves backwards. If 

the car runs slowly or 

cannot run with a fully charged balloon, refer to the following 

step. 
Turn the switch to “warm up” position. Leave the car until it 

fully  consumes  the  hydrogen  and  activates  the  fuel  cell. 

Turn  the  switch  to  the  “off”  position.  Repeat  refueling 

process again to fill storage container with hydrogen.

It is estimated that on a full tank and after “warm up” the 

H-racer  2.0  will  run  up  to  several  minutes.  Once  the 

operation is complete and the balloon is full, make sure you 

turn the hydrogen station to the “off” position. 

ON OFF WARM

 

UP

Place  two  1.5V  AA  alkaline  batteries  inside  the 

battery  compartment  as  indicated,  then  close  the 

battery compartment.

Reviews: