WARNING! BEFORE USING THE MACHINE READ THE INSTRUCTION MANUAL
CAREFULLY!

Our automatic transfer switch

are designed to give safe anddependable

service if operated according to instructions.
Read and understand the

anual before operating the automatic transfer switch

. Failure to do so could result in personal injury or equipment damage.

FUBAG

FUBAG

m

www.fubag.ru

O

m

perator's

anual

1. Safety rules

- T

- O

- I
- P
- P
- R
- M

he scheme of the device includes parts and units, who are under voltage. It is strictly prohibited to

work while the front panel of the switch is taken off.

nly the specialists, who came through the training, instructions and were tested upon the

knowledge of the electric safety requirements, having the qualification group of the electric safety
not lower than the 3rd and special certificate, are allowed to wrk with this device.

t is prohibited to use the device in the absence of ground connection or its failure.

lace the device indoors, so that the control panel is easily accessible.
lace the device on flat, strong surface.

ead this manual carefully.

aintenance and repair should be done only by qualified service center specialists.

2. echnical characteristics

T

Unit`s maintenance conditions requirements:

Package contents:

Altitude above sea level – not more than 2000 m;

Operating ambient temperature – from -20 C to +55 C;
Relative humidity – not more than 85%.

Automatic transfer switch – 1 pc;
Control cable – 1 pc.

O

O

Characteristics

STARTMASTER

BS 11500

STARTMASTER

BS 11500 D

Phase

1

3

Rated voltage mains, V

220

220/380

Rated voltage generator, V

230

230/400

Rated current load, А

50

25

Frequency, Hz

50

50

Rated voltage generator battery, V

12

12

Rated voltage battery charge ATS out, V

13,2

13,2

Rated current battery charge, А

0,7

0,7

Dimension, LxWxH, mm

350х245х147

350х245х147

IP

IP20

IP20

Weight, kg

5,3

5,3

Summary of Contents for STARTMASTER BS 11500

Page 1: ...www fubag ru STARTMASTER BS 11500 FUBAG 495 641 31 31 info fubag ru www fubag ru Operator s Manual Automatic transfer switch STARTMASTER BS 11500 D...

Page 2: ...e are allowed to wrk with this device t is prohibited to use the device in the absence of ground connection or its failure lace the device indoors so that the control panel is easily accessible lace t...

Page 3: ...power cable Connection of generator output mains input and reserved electric devices is provided by terminal screws placed inside the unit The front panel of theATS contains control buttons and mode i...

Page 4: ...in summer mode i in winter mode in seconds after successful start If there is no output voltage after electric starter relay shuts off the system will attempt to start the engine up to 5 times more I...

Page 5: ...ife During the transportation and storage of the device please keep it away from moisture It is recommended to keep the device in a dry well ventilated room and to avoid exposing it to increased humid...

Page 6: ...w fubag ru FUBAG III 1 2 2000 20 55 85 1 1 O O 5 STARTMASTER BS 11500 STARTMASTER BS 11500 D 1 3 220 220 380 230 230 400 50 25 50 50 12 12 13 2 13 2 0 7 0 7 350 245 147 350 245 147 IP IP20 IP20 5 3 5...

Page 7: ...www fubag ru 6 3 Startmaster BS 500 Fubag 11 D 1 2 3 4 5 6 7 8 9 10 Startmaster BS 00 115 Startmaster BS 00 115 D L N L N L N U1 V1 W1 N U2 V2 W2 N U3 V3 W3 N...

Page 8: ...4 Startmaster BS 500 4 5 7 5 4 5 15 5 5 10 10 11 D 1 2 10 25 8 9 10 1 2 3 5 www fubag ru 7...

Page 9: ...4 3 5 5 6 6 1 2 3 4 6 5 3 6 7 8 www fubag ru 8...

Reviews: