35
SAFETY AND MAINTENANCE
Water drainage
1. During dehumidifying
During dehumidifying, additional water is extracted from the air� Therefore,
remove the drain plug, connect a drain hose to the water drain connection
during the dehumidifying process and route this hose to a lower positioned
water drain�
Make sure that the hose is attached firmly and does not leak. Direct the
hose to the drain and make sure that it does not bend, which would stop
the flow of water. Once you finish using the hose, then put the drain plug
and knob back to prevent leakage�
2. During the cooling process
During this process, water is extracted from the air� This largely evaporates,
but any excess water accumulates at the bottom water reservoir� When
the water reservoir is full, the display will show E4� The motor and the
compressor will stop working, but not the fan�
Switch off the airco and remove the plug from the socket�
Move the airco to a drain location and empty the water reservoir by
removing the drain plug and connecting a hose� Make sure that as soon as
the water reservoir is empty, the drain plug is securely re-inserted to prevent
leakage� The symbol E4 disappears� If the error recurs, contact
your supplier�
Safety
The Fuave portable airco is equipped with overheating protection, which
switches off the airco when it overheats� When this happens, you must
remove the plug from the socket and let the appliance cool down for at
least 30 minutes� Eliminate the cause of the overheating: Was the appliance
covered or partly covered? Does it stand too close to a wall or another
obstacle, resulting in insufficient air sucked in or blown out?
Afterwards, you can use your appliance again in the usual manner, but
first keep on eye on it for the first 30 minutes to see whether no problems
recur� If the appliance shows deviations or it overheats again without any
explainable reasons, then contact your supplier or a certified electrician for
checking and/or repairing�