> Power Management
If during COOL, the room temperature is lower than the set temperature,
the airco will automatically operate in energy-saving function after an
interval. The compressor shuts down and the fan starts working on LOW.
When the room temperature rises again above the set temperature, then
the compressor and fan will start working normally and the energy-saving
function will switch off.
Remark:
When you cool or dehumidify, always wait 3 minutes after
switching ON or OFF before you switch the airco ON or OFF again. The
compressor needs this time to recover.
Water drainage
1.
During dehumidifying
During dehumidifying, additional water is extracted from the air. Therefore,
remove the drain plug, connect a drain hose to the water drain connection
(10) during the dehumidifying process and route this hose to a lower
positioned water drain.
Make sure that the hose is attached firmly and does not leak. Direct the
hose to the drain and make sure that it does not bend, which would stop
the flow of water. Once you finish using the hose, then put the drain plug
and knob back to prevent leakage.
continuous
drain hose
remove the
drain plug