User’s manual · TSQ 310 CI
- 12 - TSQ 310 CI version_en_1.0 FTE maximal
- Deactivating all decrypted: From this option you can remove all the services that
are decoding the conditional access card.
PRO 201
Note: From PRO 201 programmer you can only carry out the programming of a single module, in order to carry
out the programming of several modules at the same time you have to use a mediaMAX EVO or mediaMAX
MINI series field strength meter.
When you connect the PRO 201 programmer, it will proceed to recognize the
module and to show the main menu.
In the main menu are shown the different options for configuring the
transmodulator.
We have to use the “Up” and “Down” buttons of the keyboard in order to move to
the different options, and to get into the submenus we have to press “OK” button.
1. Manual
Inside the “manual” menu there are specified the different options for
setting up the input, output and modulation parameters.
1. This field shows the type of parameter that is selected at the moment.
Options: Input Sat, Out Cab, Out TV.
2. This field shows the parameter that is selected. In order to move
around the different options we have to use the “Up” and “Down” buttons
of the keyboard..
Click on OK to edit the selected parameter and
Right/Left for changing it. Once it is configured press OK.
Satellite input ( Input Sat)
In these options you will be able to configure the input parameters of the satellite
signal:
- L.O. freq (Local oscillator): Selection of the local oscillator that you wish to use:
FI, KU, C, K9750, K10000, K10600, K10700, K10750, K11250, K11300,
K11325 .
- Freq (Input Frequency (MHz)): Transponder frequency that you wish to tune. In order to introduce the frequency, press
the “OK” button and the cursor will be placed over the frequency. With the keys of the cursor, we can move through all the
digits and change the values. Press “OK” in order to save the value.
- Symbol Rate: Symbol speed required by the transponder. In order to introduce the symbol rate, press the “OK” button and
the cursor will be placed over the frequency. With the keys of the cursor, we can move through all the digits and change
the values. Press “OK” in order to save the value.
- Antenna: Feeding/tone towards the LNC. Options: 0V, 13V, 13V+22kHz, 18V, 18V+22KHz, 13V+AUT, 18V+AUT.
- DiseqC: In this option you can set the DiseqC configuration: A, B, C, D and None.
TSQ310CI *Input Sat
RF level: 013
>LO Freq: LO KU
Freq: 11509
1
2
TSQ310CI
>Manual< Config
Auto
TSQ310CI *Input Sat
Symbol Rate: 27500
>Antenna: 13V+22k
Diseqc: NONE
Summary of Contents for TSQ 310 CI
Page 1: ...TSQ 310 CI USER S MANUAL ...
Page 2: ......