FTE Maximal HCA ZM 20-65 User Manual Download Page 4

User’s Guide · HCA ZM 20-XX / HCA ZM 30-XX 

 

 

- 4 -    HCA ZM 20-XX / HCA ZM 30-XX     Version_en_1.2    FTE maximal 

Chapter 2.

 

Technical Features 

 

Ref. 

HCA ZM 20-30 

HCA ZM 20-65 

HCA ZM 30-30 

HCA ZM 30-65 

Code 

0302230 0302265 0302330 0302365 

Nr. Inputs/ Outputs 
 

1/1 1/1 

Terr. Freq. Margin. 

47-862 MHz 

85-862 MHz 

47-862 MHz 

85-862 MHz 

Terr. Gain. 

22 dB 

32 dB 

Terr. Regulation 

20 dB 

20 dB 

Terr. Equalization 

10 dB 

10 dB 

Freq. Margin Return path 

5-30 MHz 

5-65 MHz 

5-30 MHz 

5-65 MHz 

Return path Gain in 
active mode 

20 dB 

28 dB 

Return path Gain 
Regulation in active 
mode 

20 dB 

20 dB 

Return path Insertion 
looses in passive mode 

2.5 dB 

2.5 dB 

Output Level Max. 

115 dBµV 

115 dBµV 

Decoupling between 
Bands 

>20dB >20dB 

Consumption 

230V, 50-60Hz, 3W 

230V, 50-60Hz, 3.6W 

Dimension (mm) 

175 x 50 x 98 

175 x 50 x 98 

 
 
 

Chapter 3.

 

Conformity Declaration 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 
 

CONFORMITY DECLARATION

 

“WE, FTE MAXIMAL, DECLARE THAT THE PRODUCTS       

HCA ZM 20-30, HCA ZM 20-65,  

HCA ZM 30-30 AND HCA ZM 30-65 

ARE IN CONFORMITY WITH FOLLOWING DIRECTIVES 

Low Voltage Directive 2006/95/EC 

EMC Directive 2004/108/EC” 

If you wish a copy of the conformity declaration, please contact to the company 

Reviews: