Section 5
Changing Settings
27
FT702LT/D Flat Front Wind Sensor Manual
Software Version
Wind Velocity Filtering
Heater Set Point
Wind Direction Datum Rotation
Wind Direction Datum Current
Error Current
Wind Speed Range
Heater Current Limit
Date and Time of Report Generation (based on PC bios clock)
This report can be view or saved as a .CSV file and reviewed later in MS Excel or Notepad.
The location of the report file and its name can be changed by clicking L
og File Settings
button at the top of the
application.
5.5 Current Loop Test
Both current loop outputs can be automatically stepped through the 4-20mA range for test purposes. When the
loop test command is sent both loops are set to 4mA for a duration of 5 seconds. After 5s the loop current steps
by 2mA to 6mA. This process is repeated until the 20mA level is reached whereupon both loops return to the
wind measurement mode.
The current loop outputs during the test are shown in Figure 25.
Figure 25: Current Loop Test Waveform
Figure 26: FT702LT/D Set-Up and Test Program
Loop Test
To run the test select the Loop Test Tab, and click the
Start Test
button in the FT702LT/D Set-Up and Test
Program as shown in Figure 26.