PROPRIETARY INFORMATION
All information in this manual is proprietary to and the
property of FSR inc. This publication is protected by the Federal
Copyright Law, with all rights reserved. No part
of this document may be reproduced, transcribed, or transmitted,
in any form or by any means, without prior
explicit written permission from FSR inc.
Operators Safety Summary
The general safety information in this summary is for operating
personnel.
Do Not Remove Covers or Panels
There are no user-serviceable
parts within the unit. Removal of the top cover will expose
dangerous voltages. To avoid personal injury, do not remove the
top cover. Do not operate the unit without the cover installed.
Power Source
This product is intended to operate from a power
source that will not apply more than 230 volts rms between the
supply conductors or between both supply conductor and ground.
A protective ground connection by way of grounding conductor in
the power cord is essential for safe operation.
Grounding the Product
This product is grounded through the
grounding conductor of the power cord. To avoid electrical shock,
plug the power cord into a properly wired receptacle before
connecting to the product input or output terminals. A protective-
ground connection by way of the grounding conductor in the power
cord is essential for safe operation.
Use the Proper Power Cord
Use only the power cord and
connector specified for your product. Use only a power cord that is
in good condition. Refer cord and connector changes to qualified
service personnel.
Use the Proper Fuse
To avoid fire hazard, use only the fuse having
identical type, voltage rating, and current rating characteristics.
Refer fuse replacement to qualified service personnel.
Do Not Operate in Explosive Atmospheres
To avoid explosion,
do not operate this product in an explosive atmosphere.
IONS
SYNC INPUTS
Impedance:
470 ohms
Type:
TTL high noise immunity
Level:
1.9 volt minimum
SYNC OUTPUT
Impedance
75 Ohm
Level:
5 volts into Hi-Z, 2.4 Volts into 75 ohm load
Rise / Fall Time: 0.8 nS
Propagation
Delay: 17nS
POWER REQUIREMENTS
9 volts @ 400 mA (AC or DC).
A 9 VAC @ 1 AMP power adapter is included with two
pin Molex disconnect.
TECHNICAL SPECIFICAT
MOUNTING
Standard 19" Rack Mount Kit included
DB-9 Control I/O Pinout
PIN
FUNCTION
1
SWITCH 1 INPUT
2
SWITCH 3 INPUT
3
LAMP 1 OUTPUT
4
LAMP 3 OUTPUT
5
GROUND
6
SWITCH 2 INPUT
7
SWITCH 4 INPUT
8
LAMP 2 OUTPUT
9
LAMP 4 OUTPUT
VGA Connector15 pin High Density “D” connector
Connector may be reversed depending on which side is viewed.
Pin No. Function
Pin No. Function
Pin No. Function
1 Red Video
6 Red Ground 11 ID0 (Ground)
2 Green Video
7 Green Ground
12 ID1 (No Connect)
3 Blue Video
8 Blue Ground 13 Horizontal Sync
4 Reserved
9 No Connect 14 Vertical Sync
5 Ground
10 Ground
15 No Connect