background image

PROPRIETARY INFORMATION

All information in this manual is proprietary to and the

property of FSR inc. This publication is protected by the Federal

Copyright Law, with all rights reserved. No part

of this document may be reproduced, transcribed, or transmitted,

in any form or by any means, without prior

explicit written  permission from FSR inc.

Operators Safety Summary

The general safety information in this summary is for operating
personnel.

Do Not Remove Covers or Panels 

There are no user-serviceable

parts within the unit. Removal of the top cover will expose
dangerous voltages. To avoid personal injury, do not remove the
top cover. Do not operate the unit without the cover installed.

Power Source 

This product is intended to operate from a power

source that will not apply more than 230 volts rms between the
supply conductors or between both supply conductor and ground.
A protective ground connection by way of grounding conductor in
the power cord is essential for safe operation.

Grounding the Product

 This product is grounded through the

grounding conductor of the power cord. To avoid electrical shock,
plug the power cord  into a properly wired receptacle before
connecting to the product input or output terminals. A protective-
ground connection by way of the grounding conductor in the power
cord is essential for safe operation.

Use the Proper Power Cord 

Use only the power cord and

connector specified for your product. Use only a power cord that is
in good condition. Refer cord and connector changes to qualified
service personnel.

Use the Proper Fuse 

To avoid fire hazard, use only the fuse having

identical type, voltage rating, and current rating characteristics.
Refer fuse replacement to qualified service personnel.

Do Not Operate in Explosive Atmospheres 

To avoid explosion,

do not operate this product in an explosive atmosphere.

IONS

SYNC INPUTS

Impedance:

470 ohms

Type:

TTL high noise immunity

Level:

1.9 volt minimum

SYNC OUTPUT

Impedance

75 Ohm

Level:

 5 volts into Hi-Z, 2.4 Volts into 75 ohm load

Rise / Fall Time: 0.8 nS
Propagation

Delay: 17nS

POWER REQUIREMENTS

9 volts @ 400 mA (AC or DC).
A 9 VAC @ 1 AMP power adapter is included with two
pin Molex disconnect.

TECHNICAL SPECIFICAT

MOUNTING

Standard 19" Rack Mount Kit included

DB-9 Control I/O Pinout

PIN

FUNCTION

1

SWITCH 1 INPUT

2

SWITCH 3 INPUT

3

LAMP 1 OUTPUT

4

LAMP 3 OUTPUT

5

GROUND

6

SWITCH 2 INPUT

7

SWITCH 4 INPUT

8

LAMP 2 OUTPUT

9

LAMP 4 OUTPUT

VGA Connector15 pin High Density “D” connector

Connector may be reversed depending on which side is viewed.

Pin No. Function

Pin No. Function

Pin No.     Function

1   Red Video

             6   Red Ground                11       ID0 (Ground)

2   Green Video

  7  Green Ground

 12      ID1 (No Connect)

3   Blue Video

  8   Blue Ground              13        Horizontal Sync

4    Reserved

              9   No Connect               14        Vertical Sync

5   Ground

 10  Ground

              15        No Connect