background image

Telephone 973-785-4347

F

F

F

F

FS

S

S

S

SR

R

R

R

R

Page 10

Wall Plates

Size:

6 1/4 inches wide by 4 1/2 inches high, approximately 2.5 inches deep

Mounting:

fits standard 2 or 3 gang electrical wall box with four or 6 screws

Switches:

membrane

Connector:

5 pin connector

Cable:

West Penn #3651 or 3751 (see page 13 for details)

Power Supply  (PSA)

Size:

3 1/2 inch high, 6 inches deep, 10 inches long (approximately)

Mounting:

rear rack rail

Input power:

105 to 132 VAC, 50/60 Hz, 100 watts

Output:

+15 volts, +25 volts, -25 volts nominal

Fuse:

2 amp

Switch: power on/off (lighted rocker switch)
Interconnect:

8 foot cable supplied, 5 conductor stranded

Indicators:

three LED indicators, one for each of the unregulated voltages

MON  Monitor/VU Panel Assembly (optional)

Monitor/VU Panel

Input:

70Volt speaker level

Size:

19 inches wide, 5 1/4 inches high(3RU), 4 1/2 inches deep overall

Mounting:

standard rack rails

Monitor Relay Card (supplied with the Monitor/VU card)

Size:

3 1/4 inches wide, 9 1/2 inches long, 1 inch high, comes already mounted in a
19 inch FSR TRAC-BRAC

Mounting:

rear rack rails

MLH Head Table Speaker Assembly (optional)

Head Table Breakout Card  (HTBC)

Size:

3 1/4 inches wide, 2 3/4 inches long, 1/2 inch high

Power:

HT-PS supply provided

Head Table Relay Card  (HT-8)

Size:

3 1/4 inches wide, 7 1/4 inches long, 1 inch high, can have up to four of these
cards per system

Mounting:

rear rack rails, both the HTBC and the HT card come already mounted in a 19
inch FSR TRAC-BRAC

FM  Facility Manager Control (optional)

Facility Managers Panel  (FM-INT)

Size:

an enclosed box 3 1/2 inches wide, 5 inches long, 1 1/2 inches high

Mounting:

sits on the managers desk

Power:

a wall mounted power supply

Summary of Contents for ML-116

Page 1: ...ergen Boulevard West Paterson NJ 07424 Tel 973 785 4347 Fax 973 785 3318 E Mail sales fsrinc com Web www fsrinc com F F F F FS S S S SR R R R R INTRODUCTORY NOTES on the ML 116 THE NEW ROOM COMBINING SYSTEM ...

Page 2: ...Telephone 973 785 4347 F F F F FS S S S SR R R R R Page 2 ...

Page 3: ...ers looking for ways to make their events stand out The ML 116 fulfills the hotel and meeting centers needs and clients wishes and have been designed so if desired even the guests can play an active part in its operation FEATURES Provides for 4 background music sources Capable of combining up to 16 rooms of audio with the touch of a button Can combine up to 4 ML 116 s to control 64 rooms with full...

Page 4: ...Telephone 973 785 4347 F F F F FS S S S SR R R R R Page 4 2 GANG ML 116 WALLPLATE OVERALL VIEW OF SYSTEM COMPONENTS ...

Page 5: ...Telephone 973 785 4347 F F F F FS S S S SR R R R R Page 5 3 GANG ML 116 WALLPLATE ...

Page 6: ...ers also correspond to the numbers in each room drawn on the map panel A This3pin connectorreceivestheaudiosignalfrom the ODD room s mixer B This3pinconnectorreceivestheaudiosignalfrom theEVENroom smixer C This 3 pin connector provides the audio output to the ODD room s amplfier or EQ D This 3 pin connector provides the audio output to the EVEN room s amplfier or EQ E These four 3 pin connectors r...

Page 7: ...it K L The HTP module provides control interface to support paging capabilities It also provides the controlinterfacefortheheadtablespeakerswitching RefertosectionstitledPagingandHeadTableopera tionforadditionaldetails M Test mode dip switches and test mode indica tors These are used at the factory and are not to be operatedinthefield N Wallplate monitorinterfaceconnectors Thesefour points are whe...

Page 8: ...and moni tor panels and can talk to other Ml 116s It also controls the paging function D The HT 8 is a PC board assembly with 8 relays to control the speaker feeds to the head table locations These cards are driven by the HTBC board E The PSA Power Supply for the ML 116 system F The Monitor VU Panel permits an operator to monitor the audio from any selected room It also permits the operation of an...

Page 9: ...l Volume Reset 0 dB 1dB Full Down 18 dB 1 dB Full Up 4 dB 0 5 dB LocalInput withrespecttoinputlevel Volume Reset 0 dB 1dB Full Down 18 db 1 db Full Up 4 db 0 5 db Page Input 0 db 1 db MaximumOutputLevel 20dBm NoiseFloor 75dBmtypical Conditions Fullmix Mixer Enableson LocalInputsoff input open outputs 600 ohm terminated 70 dBm typical Conditions Full mix Mixer Enables on Local Inputs on Volume set ...

Page 10: ...ly optional Monitor VU Panel Input 70Volt speaker level Size 19 inches wide 5 1 4 inches high 3RU 4 1 2 inches deep overall Mounting standard rack rails Monitor Relay Card supplied with the Monitor VU card Size 3 1 4 inches wide 9 1 2 inches long 1 inch high comes already mounted in a 19 inch FSR TRAC BRAC Mounting rear rack rails MLH Head Table Speaker Assembly optional Head Table Breakout Card H...

Page 11: ... high 6 1 2 inches wide 5 inches deep R MAP Remote Map Panel optional Size 20 wide 14 high 2 1 8 deep Mounting standard rack rails Power 120 VAC via knockouts in case R MON Remote Monitor Panel optional Size 20 wide 5 1 4 high 2 1 8 deep Mounting standard rack rails Power 120 VAC via knockouts in case Size 8 1 2 1 1 2 high 4 3 4 deep Mounting usesuppliedrackmountingbracket Power wall wart 9 VAC Si...

Reviews: