background image

    43856                                                                                                                                                                       LIT1003 

Operators Safety Summary

 

 
The general safety information in this summary is for operating personnel. 
 

Do Not Remove Covers or Panels 

There are no user-serviceable parts within the unit. Removal of the top cover will expose dangerous voltages. To avoid personal 

injury, do not remove the top cover. Do not operate the unit without the cover installed

.

 

Power Source 

This product is intended to operate from a power source that will not apply more than 230 volts rms between the supply conductors or between both supply 

conductor and ground. A protective ground connection by way of grounding conductor in the power cord is essential for safe operation.

 

Grounding the Product 

This product is grounded through the grounding conductor of the power cord. To avoid electrical shock, plug the power cord  into a properly wired 

receptacle before connecting to the product input or output terminals.

 

A protective-ground connection by way of the grounding conductor in the power cord is essential for 

safe operation.

 

Use the Proper Power Cord 

Use only the power cord and connector specified for your product. Use only a power cord that is in good condition. Refer cord and 

connector changes to qualified service personnel.

 

Use the Proper Fuse 

To avoid fire hazard, use only the fuse having identical type, voltage rating, and current rating characteristics. Refer fuse replacement to qualified 

service personnel.

 

Do Not Operate in Explosive Atmospheres 

To avoid explosion, do not operate this product in an explosive atmosphere. 

 

Terms In This Manual

 

 

WARNING    Highlights an operating procedure, practice, condition, statement, etc., which, if not strictly observed, could result in injury to or death of personnel.      NOTE  
Highlights an essential operating procedure, condition or statement. 
 

CAUTION    

  The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) 

instructions in the literatureaccompanying the appliance. 
 
AVERTISSEMENT! 
Le point d´exclamation dans un triangle equilatéral signale à alerter  l´utilisateur qu´il y a des instructions d´operation et d´entretien tres importantes dans 
la litérature qui accompagne l´appareil. 

 

 

VORSICHT ein Ausrufungszeichen innerhalb eines gleichwinkeligen Dreiecks dient dazu,den Benutzer auf wichtige Bedienungs-und Wartungsanweisungen in der Dem Great 
beiliegenden Literatur aufmerksam zu machen.
 
 
 
WARNING 
The rear panel ON/OFF switch does not disconnect the unit from input AC power. To facilitate disconnection of AC power, the power cord must be connected to 
an accessible outlet near the unit. Building Branch Circuit Protection: For 115 V use 20 A, for 230 V use 8 A.
 
 
WARNING 
When the CVD-144 is used in the 230-volt mode, a UL listed line cord rated for 250 volts at 15 amps must be used and must conform to IEC-227 and IEC-245 
standards. This cord will be fitted with a tandem prong-type plug.

 

TERMS AS MARKED ON EQUIPMENT

 

 

CAUTION   Highlights an operating procedure, practice, condition, statement, etc., which, if not strictly observed, could result in injury to or death of personnel. 

 

CAUTION   

  The exclamation point within an equilateral triangle is intended to alert the    user to the presence of important operating and maintenance (servicing) 

instructions in the literatureaccompanying the appliance. 

 

AVERTISSEMENT! 

  Le point d´exclamation dans un triangle equilatéral signale à alerter    l´utilisateur qu´il y a des instructions d´operation et d´entretien tres 

importantes dans la litérature qui accompagne l´appareil 

 

VORSICHT  

  Ein Ausrufungszeichen innerhalb eines gleichwinkeligen Dreiecks dient dazu, den Benutzer auf wichtige Bedienungs-und Wartungsanweisungen in der 

Dem Great beiliegenden Literatur aufmerksam zu machen. 

 

 

NOTE   This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the users own expense. 

 

 
 
 
 
 
 
 
 

 

Summary of Contents for CVD - 144

Page 1: ...43856 LIT1003 USER MANUAL CVD 144 Distribution Amplifier 244 Bergen Boulevard West Paterson NJ 07424 Tel 9737854347 FAX 9737853318 Web www fsrinc com ...

Page 2: ...prietary to and the property of FSR inc This publication is protected by the Federal Copyright Law with all rights reserved No part of this document may be reproduced transcribed or transmitted in any form or by any means without prior explicit written permission from FSR inc ...

Page 3: ...instructions d operation et d entretien tres importantes dans la litérature qui accompagne l appareil VORSICHT ein Ausrufungszeichen innerhalb eines gleichwinkeligen Dreiecks dient dazu den Benutzer auf wichtige Bedienungs und Wartungsanweisungen in der Dem Great beiliegenden Literatur aufmerksam zu machen WARNING The rear panel ON OFF switch does not disconnect the unit from input AC power To fac...

Page 4: ...nd one 1x4 D A s and one 1x16 D A To insure the highest possible signal quality all outputs are fully buffered and the measured bandwidth from input to any output is greater than 350MHz with a flat signal response The CVD 144 s extended bandwidth makes it compatible with all analog video signals including HDTV In addition each of the block s inputs may be used independently or in concert to distri...

Page 5: ...ctor to output connector when fully bridged all outputs connected Differential Phase Error 0 04 degrees NTSC Differential Gain Error 0 04 NTSC Video Input Each Block 4 blocks total Number Signal Type 1 analog video NTSC PAL or SECAM Connectors 1 BNC Female Video Level 0 7Vp p nominal 2 0Vp p maximum Impedance 75 ohm Maximum DC offset 1 2V with 0 7Vp p signal Video Output Each Block 4 blocks total ...

Page 6: ...input and output connections are BNC female chassis mount connectors They will accept anlog video in NTSC PAL or SECAM formats The power cord entry accepts the supplied IEC power cordset at 110 220 VAC 50 60 Hz Typical configuration options are illustrated on the following pages ...

Page 7: ...onitor r o t i n o M r o t i n o M Monitor Monitor Monitor Monitor DISTRIBUTION AMP 1 DISTRIBUTION AMP 2 DISTRIBUTION AMP 3 DISTRIBUTION AMP 4 LINK ON OFF LINK ON OFF LINK ON OFF FSR I O CVD 144 POWER IN 100 240 VAC 47 63 hZ 0 5A 25A Y Pb Pr Projector Projector Projector VCR OR DVD PLAYER USING COMPONENT VIDEO DISTRIBUTION AMP 1 DISTRIBUTION AMP 2 DISTRIBUTION AMP3 DISTRIBUTION AMP 4 TYPICAL COMPO...

Page 8: ...roducts Some states do not allow the exclusion of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date if a Warranty Registration Card was mailed in at ...

Page 9: ...43856 LIT1003 Issue date 08 02 ...