Installation and Initial Startup 

NOTE: 

Before installation, please inspect the unit. Be sure that nothing 

inside the package is damaged. 

 

Placement & Storage Conditions 

Install the UPS in a protected area that is free of excessive dust and has adequate air flow. 
Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT 
operate the UPS where the temperature and humidity is outside the specific limits. (Please 
check the specs for the limitations.) 

 

 

Connect to Utility and Charging 

Plug in the AC input cord to the wall outlet. For the best results, 
we suggest to charge the battery for at least 4 hours before 
initial use. The unit charges its battery while connecting to the 
mains. 

 

 

4 hours 

 

Connect the Loads 

Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the 
power switch of UPS unit, then devices connected to the UPS will be protected by UPS unit. 

 

 

Turn On/Off the Unit 

Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing 
again the power switch. 

CAUTION: NEVER 

connect a laser printer or scanner to the 

UPS unit. This may cause damage to your equipment. 

Summary of Contents for FP 400

Page 1: ...it EN Quick Guide 2 Product Overview Front View Power Switch UPS status LED AC Mode green lighting Battery Mode green flashing Back View A Output receptacles B AC input Options C Circuit breaker Fuse D USB port E Modem phone or Network surge protection Line Interactive UPS Quick Guide V 2 0 ...

Page 2: ...ons Connect to Utility and Charging Plug in the AC input cord to the wall outlet For the best results we suggest to charge the battery for at least 4 hours before initial use The unit charges its battery while connecting to the mains 4 hours Connect the Loads Plug in the loads to output receptacles on the rear panel of the UPS Simply turn on the power switch of UPS unit then devices connected to t...

Page 3: ...ng is a must during UPS installation in order to reduce leakage current below 3 5mA ATTENTION Even when the UPS is disconnected from the mains there may still be hazardous voltage from the battery The battery should therefore be disconnected at the plus and minus terminals of the battery before maintenance or service work inside the UPS is performed CAUTION Servicing of batteries should be perform...

Page 4: ...d Battery voltage is too low Charge the UPS at least 6 hours Battery defect It might be due to high temperature operation environment or improper operation to battery Replace the battery with the same type of battery The mains is normal but LED is flashing Power cord is loose Reconnect the power cord securely 6 Specifications Model FP 400 FP 600 FP 800 CAPACITY 400 VA 240 W 600 VA 360 W 800 VA 480...

Page 5: ...5 ...

Reviews: