6. Gasket.
 GASKET INSTALLATION
Clean the gasket groove.
Slip the gasket over the filter and into
the groove.
Make sure the gasket is not twisted
and the bevelled edges are facing out.
Apply a small amount of sanitary
O-ring lubricant to the outside
of the gasket.
Use only FSI replacement gaskets.
Refer to Figure 2
(See Warnings)

7. Opening and Closing the Filter.
 OPENING

To isolate the filter:

1. Turn off and lock out pump.

2. Turn off inlet shutoff valve.

3. Turn off outlet shutoff valve.

4. Drain filter (vent valve may have

 to be cracked open).

5. Filter should have no internal

 pressure.

6. Check pressure gauge for zero PSI.

7. Remove lid manually by turning

 counterclockwise.
 A gentle tap against the handle may
 be necessary, if the lid was
 over tightened.

Refer to Figure 1

Remove filter bag or cartridge with
caution. Insert new filter bag,
or cartridge.
Note: The recommended differential
pressure across a filter element
before changing is: 10-15 PSI for
bag filters, 10-15 PSI for cartridges.

WARNINGS

Vent valve exhaust can be dangerous
— direct exhaust to a safe place.

Do not open vessel under pressure;
escaping fluid under pressure can
cause serious injury.

Gasket can fail, causing serious injury.
Gasket material must be chemically
and temperature compatible with
fluid being filtered.

5

(Figure 2)

Summary of Contents for x100

Page 1: ...X1 00 CONVERTIBLE FILTER HOUSING TM READ AND UNDERSTAND ENTIRE MANUAL BEFORE OPERATINGTHISVESSEL OPERATOR STUDY GUIDE INSTALLATION OPERATION MAINTENANCE ...

Page 2: ...r Elastomers Dow Chemical Resistance Guide DuPont Chemical Resistance and Fluid Compatibility Failure to comply with the chemical compatibility guidelines may result in extensive vessel structural integrity failure Such failure could result in severe injury to the user Hot and or chemically active liquids can cause serious injury Wear protective face shield and clothing X100 FILTER VESSEL SAFETY 1...

Page 3: ...er pressurized This can be achieved by installing a system relief valve 4 Mounting Location Locate the filter away from direct sunlight and all heat sources that could elevate its temperature beyond the maximum allow able See lid for maximum temperature rating MOUNTING Hard pipe the filter housing in place with 2 inch sch 80 plastic piping Secure the inlet and outlet pipe to provide filter support...

Page 4: ...essure gauge temperature gauge or the vent valve It is the responsibility of the end user to obtain install and maintain the proper components Refer to Figure 1 See Warnings 4 Figure 1 INLET SHUTOFFVALVE IN VENTVALVE PRESSURE GAUGE DIFFERENTIAL PRESSURE GAUGE TEMPERATURE GAUGE OUT OUTLET SHUTOFF VALVE DRAINVALVE ...

Page 5: ...ter should have no internal pressure 6 Check pressure gauge for zero PSI 7 Remove lid manually by turning counterclockwise A gentle tap against the handle may be necessary if the lid was over tightened Refer to Figure 1 Remove filter bag or cartridge with caution Insert new filter bag or cartridge Note The recommended differential pressure across a filter element before changing is 10 15 PSI for b...

Page 6: ...TER BAG Figure 4 Insert filter bag into the basket Make sure the bag seal ring bottoms out against the basket shoulder The ring seals against the filter wall Figure 5 Insert the self centering filter cartridge Stop when it bottoms out on the cartridge plate INLET INLET GASKET STOP TURNING WHEN THIS LUG IS CENTERED WITH THE INLET 2 3 4 TURNS TO PREVENT LEAKS KEEP GASKET AND AREA LUBRICATED AND CLEA...

Page 7: ...X100 FILTER VESSEL 7 ...

Page 8: ...artridge Plate 2 Plastic Leg and Foot Assembly Carbon Steel Tripod Legs 304 Stainless Steel Tripod Legs Lid Gasket BUNA Lid Gasket VITON Plate Gasket BUNA Plate Gasket VITON Patents Pending Filter Bags X01 Part No Price BPONG1X01 BPONG5X01 BPONG10X01 BPONG25X01 BPONG50X01 BPONG100X01 Part No Price BPMO100X01 BPMO150X01 BPMO200X01 BPMO300X01 BPMO600X01 BPMO800X01 Cartridges X20 Part No Price CMMF 1...

Reviews: