6. Gasket.
GASKET INSTALLATION
Clean the gasket groove.
Slip the gasket over the filter and into
the groove.
Make sure the gasket is not twisted
and the bevelled edges are facing out.
Apply a small amount of sanitary
O-ring lubricant to the outside
of the gasket.
Use only FSI replacement gaskets.
Refer to Figure 2
(See Warnings)
7. Opening and Closing the Filter.
OPENING
To isolate the filter:
1. Turn off and lock out pump.
2. Turn off inlet shutoff valve.
3. Turn off outlet shutoff valve.
4. Drain filter (vent valve may have
to be cracked open).
5. Filter should have no internal
pressure.
6. Check pressure gauge for zero PSI.
7. Remove lid manually by turning
counterclockwise.
A gentle tap against the handle may
be necessary, if the lid was
over tightened.
Refer to Figure 1
Remove filter bag or cartridge with
caution. Insert new filter bag,
or cartridge.
Note: The recommended differential
pressure across a filter element
before changing is: 10-15 PSI for
bag filters, 10-15 PSI for cartridges.
WARNINGS
Vent valve exhaust can be dangerous
— direct exhaust to a safe place.
Do not open vessel under pressure;
escaping fluid under pressure can
cause serious injury.
Gasket can fail, causing serious injury.
Gasket material must be chemically
and temperature compatible with
fluid being filtered.
5
(Figure 2)
➔
Summary of Contents for x100