311 Abbe Rd.

 

Sheffield Lake, Ohio 44054

 

Phone: 440

-

949

-

2400

 

Fax: 440

-

949

-

2900

 

Email: [email protected]

 

Visit us on the web at www.fsinorth.com

 

CONSTRUCTION HEATER GENERAL HAZARD WARNING

 

READ INSTRUCTIONS CAREFULLY. READ AND FOLLOW ALL INSTRUCTIONS. PLACE             

INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE. DO NOT ALLOW ANYONE WHO 

HAS NOT READ THESE INSTRUCTIONS TO ASSEMBLE, LIGHT, ADJUST OR OPERATE THE 

HEATER.

 

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION 

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

 

SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN.

 

UNVENTED PORTABLE HEATERS USE MR (OXYGEN) FROM THE AREA IN WHICH IT IS USED. 

ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED. REFER TO                

INSTRUCTIONS.

 

 

WARNING

 

FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.

 

KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A 

SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS. 

NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE 

COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST 

PARTICLES OR UNKNOWN CHEMICALS.

 

 

WARNING

 

COMBUSTION BY

-

PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON 

MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND 

BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM).

 

 

WARNING

 

NOT FOR HOME OR RECREATIONAL VEHICLE USE

 

We cannot anticipate every use which may be made for our heaters. CHECK WITH YOUR LOCAL 

FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL REGULATIONS.

 

Other standards govern the use of fuel gases and heat producing products in specific applications. 

Your local authority can advise you about these.

 

 

FOR YOUR SAFETY

 

DO NOT USE THIS HEATER IN A SPACE WHERE GASOLINE OR OTHER LIQUIDS HAVING 

FLAMMABLE VAPORS ARE STORED OR USED.

 

 

IMPORTANT

 

Heater is designed for use as a construction heater. Heater is not intended for use in pest remediation. 

The primary purpose of construction heaters is to provide temporary heating of buildings under       

construction, alteration, or repair and to provide emergency heat. Properly used, the heater provides 

safe, economical heating. Products of combustion are vented outside the area being heated.

 

 

This heater is designed and approved for use as a construction heater under CSA B140.8 Portable Oil 

Fired Heaters; UL 733; UL 296.

 

We cannot anticipate every use which may be made of our heaters. CHECK WITH YOU LOCAL FIRE 

SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.

 

Other standards govern the use of fuel gases and he at producing products in specific applications. 

Your local authority can advise you about these.

 

Summary of Contents for F-HVF1101

Page 1: ... Lake Ohio 44054 Phone 440 949 2400 Fax 440 949 2900 Email sales fsinorth com Visit us on the web at www fsinorth com 03 16 PORTABLE AIR HEATERS MANUAL FSI OIL INDIRECT FIRED AIR HEATER MODELS F HVF1101 F HVF2101 F HVF3101 ...

Page 2: ...N MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE We cannot anticipate every use which may be made for our heaters CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL REGULATIONS Other standards govern the use of fuel gases and heat producing products in spec...

Page 3: ... FUEL OIL 17 GAL 17 GAL 27 7 GAL 120 V 15 10 60 HZ 7 5 A 0 9 KW 120 V 15 10 60 HZ 7 5 A 0 9 KW 120 V 15 10 60 HZ 11 4 A 1 4 KW 135 LB 148 LB 271 LB NOZZLE 0 65 US GPH 80 S DANFOSS 1 00 US GPH 80 S DANFOSS 1 50 GPH 80 S DANFOSS PRESSURE 174 PSI 12300 KPA 12 BAR 145 PSI 1000KPA 10 BAR 174 PSI 1200KPA 12 BAR CERT TECHNICAL DATA IMPORTANT In order to have a correct function you must use an electrical ...

Page 4: ... criteria The safety devices ensure the machine always operates correctly IMPORTANT This appliance is not suitable for use by persons including children with reduced physical sensory and mental capacities or with lack of experience or knowledge unless supervised by a person responsible for their safety Children must be supervised to make sure they do not play with the appliance DANGER Suffocation ...

Page 5: ...5v supply must be available Please note that the heater requires minimum 15 amps for proper operation Ensure appropriate gauge extension cord is used 12 3 AWG at 50 Ft 10 3 AWG at 100 Ft 2 2 7 The recommended safety distances between heaters and flammable substances are front output 5 ft side top output 2 ft 2 2 8 Avoid fire hazards by placing the hot or functioning heater on a flat level surface ...

Page 6: ...et button turns on with a steady red light pic 5 it means the heater needs to be reset To reset the heater press the reset button all the way down pic 6 Identify and remove the cause that stopped the appliance for instance obstruction of air intake and or outlet total block of the fan etc Please contact an appointed service center for assistance in case it is impossible to solve the problem 7 3 SW...

Page 7: ...8 4 FUEL PUMP FILTER See the preventive maintenance schedule 9 STORAGE AND TRANSPORT IN ORDER TO KEEP THE HEATER IN THE BEST POSSIBLE CONDITIONS WE RECOMMEND TO FOLLOW THE BELOW PROCEDURE 9 1 Empty the fuel by removing the drain cap at the bottom of the tank pic 5 Dispose of the fuel in an appropriate container in accordance with the current safety regulations 9 2 To remove any residual remaining ...

Page 8: ...he working environment temperature pic 4 6 Top off fuel and reset heater 7a Empty rinse and refill the tank 7b Rinse the filters SEE PAR 8 7c Contact a service center Smoke while operating 1 External substances or dirt in the fuel circuit 2 Obstructed inlet air vent 1a Empty and refill the tank with clean fuel 1b Rinse fuel filters 1c Contact a service center 2 Remove all air vent obstructions The...