FSHS PuROMax Installation Instructions Manual Download Page 4

Recommended tools: 
Center punch 
Variable speed drill 
High speed drill bits 
Greenlee chassis punch 7/8" (or 9/16" for non air gap faucets) 
Protective gloves & eye protectors 

Procedures: 
A. Center punch small indent for hole. 
B. Drill the required pilot hole. 
C. Set-up the chassis punch per instructions and tighten nut to cut the desired hole size. 
D. Clean up sharp edges with file. 
 

2. Mounting the faucet 

Disassemble hardware from the threaded nipple, except for chrome base plates and rubber washers. 
(Rubber washers may be replaced with bead of plumber's putty for neater appearance.) Feed the threaded nipple through 
sink or counter mounting hole and orient the faucet. From below sink or counter, assemble the white spacer flat washer 
and hex nut on threaded nipple and tighten by hand. (Open end up; open side toward air gap). After checking faucet 
orientation, tighten with a wrench until secure. 

 
3. Feed water valve and tubing installation 

The saddle tapping valve which is supplied is designed for use with 3/8" to 1/2" OD soft copper supply tubing (plain or 
chromed) and rigid metal pipe. Do not use with flexible ribbed supply tubing which is too thin and requires special 
hardware.  

 

Self-taping feed water saddle valve installation 

Installation procedures using soft copper tubing: 
1. Turn off cold water valve from under sink or main water line valve for whole house. 
2. Before installing saddle tapping valve, make sure piercing lance does not protrude beyond rubber gasket. 
3. Assemble saddle valve on copper tubing. 
4. Turn handle clockwise to pierce soft copper tube until valve is firmly seated. (Valve is closed in this position.) 
5. Turn on water supply to pressure cold water line. 
6. Snug nut/seal with wrench around valve stem 
7. Connect tubing to feed water valve using brass compression nut, insert and plastic sleeve. 
 
Saddle valve installations with metal pipe: 
1. Turn off cold water supply. 
2. Drill 3/16" hole at desired location. 
3. At this point, make sure piercing lance does not protrude beyond rubber gasket. 
4. Assemble saddle on to pipe, aligning with hole. 
5. Turn saddle valve handle clockwise to close valve. 
6. Tighten nut/seal around valve stem with wrench. 
7. Connect tubing to feed water valve using brass compression nut, insert and plastic sleeve. 
8. Turn on cold water supply. 
9. To open valve, turn handle counterclockwise and check for leaks. 

 
 
4. Drain saddle valve installation 

Summary of Contents for PuROMax

Page 1: ...FSHS Inc 23380 Janice Ave 5 Port Charlotte FL 33980 PuROMax Reverse Osmosis ...

Page 2: ...ve senses when the storage tank is full and closes the water supply to conserve water The dedicated faucet is used to dispense RO produced water when needed Feed water saddle valve is connected to the cold water line to supply water to the R O system Waste water saddle valve is connected to the drain to remove reject water from the R O system Tubing supplies feed and reject water Fittings are used...

Page 3: ...surface is required not exceeding 1 1 4 in thickness Drill the required pilot hole for the chassis punch and tighten nut to cut the desired hole size Clean up sharp edges The faucet should be positioned so it empties into the sink and the spout swivels freely for convenience If sink has a hole that can accommodate the RO faucet no drilling is required Proceed with mounting the faucet Porcelain Ena...

Page 4: ...se with flexible ribbed supply tubing which is too thin and requires special hardware Self taping feed water saddle valve installation Installation procedures using soft copper tubing 1 Turn off cold water valve from under sink or main water line valve for whole house 2 Before installing saddle tapping valve make sure piercing lance does not protrude beyond rubber gasket 3 Assemble saddle valve on...

Page 5: ...it installation The RO unit is normally mounted to the right or left sink cabinet sidewall depending on where supply tank is to be located Generally the unit is installed at the front of the cabinet and the tank at the rear To mount the unit elevate it at least 2 off the floor level it and mark the location of mounting holes needed Drill holes for mounting screws and install screws allowing the mo...

Page 6: ...rrect leaks if leaks occur 3 Open valve on storage tank and open faucet until a steady stream of water flows 4 Close faucet and wait five minutes to see if leaks result Note When the system is first turned on water may intermittently spurt from the air gap opening on the side of air gap faucets This is common and should correct itself after an initial period of time Flushing system and checking op...

Page 7: ...ove protective wrap from pre filters and membrane and install them in the appropriate filter housings Hand tighten and snug with wrench if necessary 13 Replace post carbon in line filter if necessary Note Be sure to check o rings are in place when installing cartridges in filter housings Damaged or incorrectly placed o rings will cause leaks 14 Disconnect product water tubing from the holding tank...

Page 8: ...eneral the higher the pressure differential and temperature increased quality and quantity of water is produced These factors should be considered when sizing RO systems for a particular application PuROMax brand fittings Many RO systems utilize PuROMax brand fittings These user friendly fittings provide superior performance and may be provided with this system Proper use of these push in fittings...

Page 9: ...PuROMaxtm 3 Stage Permeate Pump R O 3 8 Parts list available upon request ...

Page 10: ...PuROMaxtm 4 Stage R O ...

Page 11: ...PuROMaxtm 5 Stage R O ...

Page 12: ...PuROMaxtm 4 Stage R O 3 8 ...

Page 13: ...PR HN0404 1 4 Hex Nipple 2 19 PR CV0201W Automatic Shut Off Valve 1 7 FM 60 Triple Bracket 1 20 FR Flow Restrictor 1 8 C 2500W Single Clip Membrane Housing 2 21 PR MRT0604 Quick Connect 1 4 x 3 8 x 3 8 Male Run T 1 9 PR CV3142 Quick Connect 1 4 tube x 1 8 thread with check valve 1 22 TFM Membrane 1 10 DC 2500W Double Clip Membrane Housing To Inline 2 23 PE 12 BI 0500F Y 3 8 Yellow Tubing 5ft 11 MH...

Page 14: ...manufacturer of these parts and their warranty LIMITED WARRANTY The REVERSE OSMOSIS MEMBRANE will be warrantied for a three month shelf life and a twelve month in use period for a total fifteen months Warranty begins from the date of purchase from the manufacturer Membrane is warrantied against defects when used under standard operating conditions Membranes must be kept moist at all times Defectiv...

Reviews: