Curtis-Toledo Rotary Compressor
CAP862
Operations and Maintenance Manual
Chapter 6 Page 10
CAUTION
CAUTION
CAUTION
CAUTION
Over greasing is a major cause of bearing and motor failure.
Make sure not to over grease or to introduce any contaminants during
greasing.
To regrease the bearings:
Switch off the unit, disconnect the power, and lockout and tag to prevent accidental
restarting.
1.
Clean grease fittings.
2.
Remove the relief plug and free the hole of hardened grease.
3.
Add grease with hand operated grease gun until it appears at the shaft hole in the end
plate or the relief plug outlet.
4.
Re-connect the power, and run the unit for 20 minutes without the relief plug in place.
5.
Switch off the unit, disconnect the power, and lockout and tag to prevent accidental
restarting.
6.
Re-install the grease relief plug.
7.
Return unit to service.
WARNING
WARNING
WARNING
WARNING
Rotating machinery can cause injury or death. Open main disconnect,
tag and lockout power supply to the starter before working on the
electric motor
Summary of Contents for SE Series