background image

 

 

CAP-837 

"Air circuit" and "Oil circuit" 
screen 

 

 

 

Fig. 8: "Air circuit" screen 

Tap the 
circuit and oil circuit are displayed schematically.

 

 

Fig. 9: "Oil circuit" screen 

Tap the button to the 

 

"Graphics" screen 

 

 

 

Fig. 10: "Graphics" screen 

The "Graphics" button initially leads to an overview of all existing 
graphical evaluation. The pressure, temperature, air quantity, usage 
and maintenance intervals are displayed.

 

 

Fig. 11: "Pressure" screen 

In the "Pressure" screen the pressure of the system is graphically 
displayed.

 

iCommand 

18

 

Tap the 

"State"

 button and the compressor stage is shown. The air 

circuit and oil circuit are displayed schematically. 

Tap the button to the 

"right"

 to get to the "Oil circuit" screen.

The "Graphics" button initially leads to an overview of all existing 
graphical evaluation. The pressure, temperature, air quantity, usage 
and maintenance intervals are displayed. 

In the "Pressure" screen the pressure of the system is graphically 
displayed. 

 iCommand – Touch 

iCommand - Touch 

button and the compressor stage is shown. The air 

to get to the "Oil circuit" screen. 

The "Graphics" button initially leads to an overview of all existing 
graphical evaluation. The pressure, temperature, air quantity, usage 

In the "Pressure" screen the pressure of the system is graphically 

Summary of Contents for Nx Series

Page 1: ...nd or equipment damage will be result by failing to pay attention to the vital safety information and instructions in this manual Carefully read understand and retain all safety information and instructions before operating this compress Series OPERATOR MANUAL CAP 837 June 2015 Rev B attention to the vital safety information and instructions in this manual Carefully read understand and retain all ...

Page 2: ......

Page 3: ...t must not be uti and or communicated except for internal pur poses without the written permission of the manu Any infringement shall be subject to compensation for damages We reserve the right to assert further Limitation of liability All information and instructions in this manual have been compiled taking account of the applicable standards and regulations state ogy and our years of knowledge a...

Page 4: ...Operating parameters menu 2 7 3 Maintenance counter menu 2 7 4 Timer menu 2 7 5 Configuration menu 2 7 6 Factory settings menu 2 7 7 Fault log menu 2 7 8 Diagnostics menu 2 7 9 LLC configuration screen 2 7 10 SD Card menu 2 8 Messages 2 8 1 Overview 2 8 2 Warning 2 8 3 Fault messages 2 8 4 Maintenance messages 3 Index Table of contents 4 Symbols in these instructions Position of the safety devices...

Page 5: ...perating or handling this equipment Symbols in these instructions The safety instructions and safety information in instructions are denoted by symbols The safety instructions are prefaced by signal words This combination of symbol and signal word indicates a directly hazardous situation which will lead to serious or n fatal injuries if not avoided This combination of symbol and signal word indica...

Page 6: ...r use also includes adherence to all d tails in this manual Any use beyond the proper use or other type of use counts as misuse WARNING Danger due to misuse The compressed air may not be used for breathing appropriate after The compressed air may not be used directly for pharmaceutical or sanitary purposes or for the direct handling of food w after treatment The screw compressor may not be operate...

Page 7: ...out and tag Do not attempt to remove any parts break any connection loosen oil fill plug or drain plug until the unit has been shut down and air pressure has been Do not operate the compressor in excess of its rated pressures and speeds indicated on the com Do not remove guards shields or screens while operation If removed for maintenance replace before resuming operation Observe the delivery pres...

Page 8: ...ts Incorrect handling of pollutants particularly incorrect waste disposal may cause serious damage to the environment Always observe the instructions below regarding handling and disposal of pollutants Take the appropriate actions immediately if pollutants escape accidentally into the environment If in doubt inform the responsible municipal authorities about the damage and ask about the appropriat...

Page 9: ...ection of rotation sticker on the drive unit and on the cooling air ventilator This sticker shows the appropriate direction of rotation 9 Instructions on the machine Danger of injury from illegible Stickers and signs can become dirty or otherwise obscured over time with the result that dangers cannot be recognized and the necessary operating instructions cannot be complied with This in turn poses ...

Page 10: ...CAP 837 Brief instructions for operation This sticker is on the enclosure and contains brief instructions for operation 10 and contains brief Safety ...

Page 11: ... the respective operating controls using a finger or stylus perform the desired entry Glove operation is also possible Brief description The ICOMMAND TOUCH controller serves to display operating data to switch on off the compressor to program the compressor iCommand Touch iCommand Touch Description of function Displays settings and operating Serves to switch on the compres Serves to switch off the...

Page 12: ...d run on Lead lag control mode LLC operation The switch on off pressure set is not taken into account by the controller The compressor is controlled by a master controller The safety pressure is the sum of the set maximum pressure If the pressure exceeds the value of the safety pressure the compressor is switched off with a fault message If the maximum pressure is exceeded by 7 PSI a warning appea...

Page 13: ...n the display Five buttons Fig 3 5 9 are located on the right hand side of the basic display which allows access to all important functions and information for the system iCommand Touch iCommand Touch This illustration contains for illustration purposes a combination of symbols which are not possible in a real The settings and operating parameters are shown in the display Five hand side of the bas...

Page 14: ...ure screen Button with display of the system state and to open the State screen Button to open the Graphics screen Button to open the menu system Display of date and time Timer pressure times active display Timer compressor active display SD Card indicates if a SD card is inserted Communication on RS485 active display Ventilator display Frost protection display Load valve open display iCommand Tou...

Page 15: ...l explanation State display If this symbol is shown then the an inverter Display LLC mode activated display of the master controller iCommand Touch iCommand Touch Remote display Remote On Off is activated Restart display Automatic restart is activated to open the symbol explanation If this symbol is shown then the compressor is Display LLC mode activated display of the ...

Page 16: ...s a fault the compressor is switched Messages are also shown in the system diagram in order to detect the source location of the warning maintenance or fault Below the sy tem diagram a status line is located which provides constant info mation about the operating mode of the system Navigation of the individual screens is done via the button in the title line The Home button leads back to the basic...

Page 17: ...asured value of the final compressor temperature is displayed in the Temperature screen A tap on the ture button graphically displays the temperature course All te perature values of the entire system are compiled on the other pages scrolling is done using the arrow key iCommand Touch iCommand Touch the basic display are allocated as follows 1 button to open the Pressure screen 2 button to open th...

Page 18: ...ton and the compressor stage is shown The air circuit and oil circuit are displayed schematically Tap the button to the right to get to the Oil circuit screen The Graphics button initially leads to an overview of all existing graphical evaluation The pressure temperature air quantity usage and maintenance intervals are displayed In the Pressure screen the pressure of the system is graphically disp...

Page 19: ...re graphically displayed Maintenance interval screen In the Maintenance interval screen the time to the next maintenance for the oil filter suction filter oil separator compressor and motor are graphically displayed iCommand Touch iCommand Touch In the Temperature screen the temperature of the system is tity is displayed in cubic feet In the Usage screen the amount of operating hours on load hours...

Page 20: ...ectangle using your fingers Zoom in The following option are available in the x direction Max All available data points are displayed Both axes are ideally adjusted for this 10 min 30 min 1 h The respective section is displayed Using the arrow keys allows scrolling in the x direction by a quarter of the selected interval X Auto The values from the menu Display parameter X Auto assumed Manually Thi...

Page 21: ... The number for the day code is displayed in the input field Fig Code Code type Access level function Description Menu Without code The menu system is di played in whole Setting can not be changed The Lock touch function is access ble 1 Menu Customer The menu system is di played in whole Setting can be changed The Lock touch function is access ble iCommand Touch iCommand Touch off process the comp...

Page 22: ...log LLC Diagnostics SD iCommand 22 Access to the menu system without a code In the menus all changeable parameter can be selected via a button see Fig 19 When accessing the menu system without a code only a value display is released Instead of a button a light blue field Fig pears The main menu includes the following submenus Control Operating parameters Maintenance counter Timer Display parameter...

Page 23: ... a value is entered Left at the edge the possible setting range the default setting as well as a brief explanation text is displayed After input the new value can be accepted or deleted Accept input and leave Correct input Discard input and close input page iCommand Touch iCommand Touch When accessing the menu system with code 1 settings are available in the controller If a code is entered all val...

Page 24: ...nter Chapter 2 7 3 Maintenance counter menu on page 34 Timer Chapter 1 6 Instructions on the machine on page Display parameters Chapter 0 Display parameters menu page 39 Configuration Chapter 2 7 5 Configuration menu Factory settings Chapter 2 7 6 Factory settings menu page 49 Fault log Chapter 2 7 7 Fault log menu on page Diagnostics Chapter 2 7 8 Diagnostics menu on page LLC Chapter 4 7 10 LLC m...

Page 25: ...ontains the following parameter Value setting Initial setting Remarks Lower limit for the pressure regulation Setting range 51 PSI Stop pressure minus 1 PSI Initial setting depending on compressor type Upper limit for the pressure regulation Setting range depending on compressor type however at above the start up pressure Initial setting depending on compressor type Lower limit for the pressure co...

Page 26: ...n load Off Initial setting Automatic Switch cy cles moni tored Activating or deactivating the switch cycles monitoring Setting range Yes No Initial setting No iCommand 26 Operating parameters menu This menu contains the following parameters Value setting Initial setting Remarks Co pressor type Automatic restart after power failure All Specifies the possibility to switch the system on or off remote...

Page 27: ...ust be set to Yes see above Setting range Yes No Initial setting No iCommand 27 Value setting Initial setting Remarks During activated switch cycles monitoring maximum amount of permitted 60 h Initial setting depends on compressor type During operation with an external LLC as LLC slave Local pressure toler ance is ignored However maximum pressure is still monitored Two inputs OK function and Remot...

Page 28: ...terval Designation can be set in the Display parameter Setting range 0 30000 h Initial setting 0 h Universal 3 maintenance interval Freely usable maintenance interval Designation can be set in the Display parameter Setting range 0 30000 h Initial setting 0 h iCommand 28 Maintenance counter menu This menu contains the following parameters Value setting Initial setting Remarks Com pressor type Time ...

Page 29: ...the compressor and the on load hours calculated air quantity of the co pressor Setting range 0 Initial setting 0 ft iCommand 29 This menu contains the following parameters Value setting Initial setting Remarks Compresso r type Operating hours Motor on 999999 h All load hours counter Motor on load valve open Operating hours All Ready hours counter System on motor off 999999 h All From the maximum a...

Page 30: ...tically calculated In addition it is also possible to activate the automatic daylight saving time This takes into account the conversion rules for the CET Central European Time Switching times compr screen In this menu the start and stop of the compressor can be defined The timer can be activated and deactivated The compressor is only released for the programmed times if the Switching times compr ...

Page 31: ...essure times compr screen In the example Fig 29 shown the pressure range was set to 123 9 5 bar on the weekend between 10 15 am and 10 30 pm To switch on a pressure range for the compressor on for one or se eral days continuously the respective days must be selected and 00 00 must be entered for switching times iCommand Touch iCommand Touch the compressor would operate at least from Monday to Frid...

Page 32: ...s if required Via the Timer Scheme 1 Fig 30 1 the channel overview for scheme 1 can be accessed This channel overview shows that Channel 1 is presently active Using the Channel 1 active Fig 31 1 button the submenu for progra ming Channel 1 can be accessed In this Fig 32 the scheme of Channel 1 can be programmed This menu contains the following submenus Dimensions Offset Chapter 2 7 4 5 Dimensions ...

Page 33: ...nsions Offset screen The pressure dimension temperature dimension volume and pre sure offset can be set in the Dimensions Offset screen Value setting Initial setting Remarks Compressor type Display unit for all pressure values Setting range bar MPA psi Initial setting psi All Display unit for all temperatures Setting range C F K Initial setting F All Display unit for volume air quantity Setting ra...

Page 34: ...cifies the upper limit of the Y the double arrow button Y iCommand 34 Settings for the illustration of the diagrams can be made in the Diagrams screen Value setting Initial setting Remarks Compressor type Specifies the recording interval for the flow diagrams 60 s All Specifies the display period of the flow diagram when 1440 min Initial setting 60 min All Specifies the lower limit of the Y axis a...

Page 35: ...ting Initial setting Remarks Compressor type ture flow diagram nge Temperature graph low 302 F Initial setting 212 F Specifies the lower limit of the Y axis after actuating the double arrow button Y restore in the volume flow diagram Setting range 0 ft t Air flow Y axis high Default setting 0 ft All Specifies the upper limit of the Y axis after actuating the double arrow button Y restore in the vo...

Page 36: ...ies the brightness of the display when the screensaver is active Setting range 0 100 Initial setting 50 iCommand 36 In this menu the settings for the screensaver can be performed Value setting Initial setting Remarks Compressor type Specifies if the Screensaver function is active Should the screensaver be active the screensaver will be shown after the delay and dimmed to Bright ness screensaver A ...

Page 37: ...on screen page 44 MK200 modules Chapter 2 7 5 1 MK200 modules screen page 45 Inputs Outputs Chapter 2 7 5 2 Inputs Outputs screen page 46 Heating ventilation Chapter 4 7 6 4 Heating ventilation screen on page 46 Compressor type Chapter 2 7 5 3 Compressor type screen on page 48 This screen shows the settings for the communication iCommand Touch iCommand Touch This function is used to clean the disp...

Page 38: ...e available Setting range Read only Read write customer Read write service Read write factory Initial setting Read write service iCommand 38 Value setting Initial setting Remarks Compressor type Specifies the protocol type on the RS485 networking MODBUS Standard All Specifies the participants address in the RS485 27 All 4800 9600 19200 38400 57600 115200 19200 All Specifies the protocol frame when...

Page 39: ... Whether the ICOMMAND TOUCH establishes a communication to a module and monitors a fault of a module depends on the settings in this menu Value setting Initial setting Remarks Compressor type Specifies if a Profibus is triggered on the MK200 module Set address 31 Setting range Yes No Initial setting No All Specifies if the expansion module on the MK200 module is being considered The assignment of ...

Page 40: ...s used to assign functions to the ICommand digital inputs and outputs and to the accessory modules Eight digital inputs and seven digital outputs are available on the ICommand Touch P These are preconfigured for the initial setting however it is possible to change if required Output 1 4 of the ICommand Touch P can be preassigned depending on compressor type Heating ventilation screen In the Heatin...

Page 41: ...Command 41 Value setting Initial setting Remarks Compressor type Setting range Yes No Initial setting No Specifies the switch on temperature for the heating system programmable output Setting range 36 F Shut down temp heating Initial setting 36 F All Specifies the switch off temperature for the heating system programmable output nge Starting temp heating 176 F Initial setting 46 F All Specifies th...

Page 42: ...e max air volume of the compressor Setting range 0 2354 Initial setting depending on compressor type iCommand 42 Compressor type screen This menu shows the settings for the compressor type Value setting Initial setting Remarks Compressor type Specifies the compressor family for further compressor All Specifies the compressor Caution When changing this specific parameters are set to their All Speci...

Page 43: ... the Factory settings menu the operating times and final compre sor temperature are displayed Value setting Initial setting Remarks Compressor type Specifies the start up time of the motor Setting range 3 30 s Initial setting depending on compressor type All Specifies the minimum run on time during manual switch off of the compressor This value is also used during restart delays after power failur...

Page 44: ... messages appear first Using the arrow buttons scroll to older messages For each entry the following information is available Entry number Warning or fault symbol Time the message cause appeared Message in plain text Currently still waiting meaning not confirmed messages flashing A new occurring message replaces the older entry once the message memory is full Diagnostics menu This menu contains th...

Page 45: ...ettings e g switch on times switch off and change inte vals can be set in the LLC configuration Fig 50 Using the button the second part of the menu can be screen Fig 52 accessed Value setting Initial setting Remarks Compressor type Indicates if and how the communication for the LLC function should be done or if a LLC module is avail Setting range No no LLC Digital LLC via expansion module RS485 LL...

Page 46: ... one more compressor is in operation Setting of 0 deactivates this function Setting range 0 Initial setting 0 iCommand 46 Value setting Initial setting Remarks Compressor type significantly exceeded Setting range Yes No Specifies if the switching off for all the LLC masters and connected slaves is possible via the ACP con trolled compressor stage Switching on or off is done via a respectively prog...

Page 47: ...he LLC for the compressor with priority 3 Setting range 1 Initial setting 24 h iCommand 47 Value setting Initial setting Remarks Compressor type Specifies the minimum time of the first switch on of a compressor Setting range 0 600 s Initial setting 5s All Specifies the minimum time of the first switch off of a compressor range 0 60 s Initial setting 2 s All Specifies the time prior to switching on...

Page 48: ... priority assignments of the individual compressors The values set here only apply if no timer channel of the timer LLC priorities is active Value setting Initial setting Remarks Compressor type Specifies a priority level for each compressor in the LLC series Compressors with high priority ware preferred when switching on Lead lag control only takes place between compressors of the same priori Set...

Page 49: ...y applies for the LLC master Programming is done analogous to other timers such as Switching times compr Chapter 2 7 4 2 Switching times compr screen The same priority levels as described in Chapter priorities screen on page 53 iCommand Touch iCommand Touch The pressure times of the LLC are defined in this menu in is only applies for the LLC master Programming is done analogous to the Pressure tim...

Page 50: ...ards can be read with this function The SD Card with the ACPParam par must be inserted This function starts data logging on the SD Card Insert a SD without write protection The following data is also written Time stamp System state Final temperature Oil temperature Air quantity State of all connected compressors only on LLC Pressure air quantity and temperatures are saved in the display p rameter ...

Page 51: ...message in plain text The message window can be closed with the quit button The warning triangle stays in the title psi until the cause of the message has been remedied The message is displayed again after a tap on the warning triangle The compressor continuous to run Remarks The maximum permissible compressor final tempera ture warning limit has been exceeded refer to the Factory settings menu Th...

Page 52: ...rofib Mod Adr 31 The Profibus module on address 31 does not r spond This monitoring is only active if this module has been selected iCommand 52 Compressor type The on W034 Speed reduction programmed digital input was opened Delay 1 s All The on W034 Dryer programmed digital input was no delay All The on W036 Condensate drain programmed digi tal input was closed All The on W037 Air filter programme...

Page 53: ...mmed digital input was opened W059 Ext War 4 The on W059 Ext War 4 programmed digital input was opened iCommand 53 Remarks During the access to the SD Card a fault occurred The on W056 Ext maint 1 programmed digital input was opened The on W057 Ext War 2 programmed digital input was opened The on W058 Ext War 3 programmed digital input was opened The on W059 Ext War 4 programmed digital input was ...

Page 54: ...e iCommand 54 Fault messages A flashing tool symbol will appear in the left top of the basic display if a fault message is present In addition a message pop up appears at the bottom of the display the message in plain text The message window can be closed with the quit button The fault icon in the title stays but only until the cause of the error has been corrected The compressor is switched off B...

Page 55: ... The digital input programmed on External fault triggered E113 Ext Err 4 The digital input programmed on External fault 4 was triggered iCommand 55 Remarks Network pressure too high The pressure has exceeded the set upper limit The system pressure switch digital input has not opened after 35 s in on load operation The accessory module on address 4 Type MK200 8E4RA does not respond This monitoring ...

Page 56: ...triangle will appear in the left top of the play if a new maintenance warning is present In addition a message pop up appears at the bottom of the display the message in plain text The message window can be closed with the quit button The warning triangle in the title psi stays but only until the maintenance has been confirmed The compressor continuous to run Compressor type Time to next maintenan...

Page 57: ...afety pressure Switching off Switching on Warning C Copyright Customer service 57 11 21 13 54 56 24 12 11 12 21 21 51 3 3 E Emergency stop button Environmental protection Coolant liquid Lubricants Explanation of symbols L Limitation of liability3 P Proper use R Relief valves S Safety Safety devices Symbols on the machine U Use iCommand Touch Index 8 8 8 5 6 8 5 7 9 6 ...

Page 58: ......

Page 59: ......

Page 60: ...Curtis Toledo Inc 1905 Kienlen Avenue St Louis Missouri 63133 www fscurtis com info fscurtis com ...

Reviews: