example, 200 – 85% = 30mg/L. So, if your test reading was approaching 30mg/L or higher, it would be time 
to change the membrane. 

Troubleshooting 

Problem 

Possible Cause(s) 

Solution 

Leaking between 
fitting & tubing 

Unseated Tube 

Check all tubing connections by firmly pushing them into the 
fitting. Check that there are no kinks or any obvious issues. If 
the problem persists, remove the tubing and check for a clean 
cut with no burs. Push the tubing back in and try again. If this 
does not work please contact customer support. 

Leaking from 
Feed Water Valve 

1. Damaged or 
Missing Washer 
 
 
2. Not Tight 
Enough 
 
 
3. Thread is too 
Short 

1. Check the valve to see if the washer is inside, if it is 
damaged it may need replacing – this is a common size 
washer and can be purchased from most hardware/plumbing 
stores. 
2. If the diverter valve is loose (or you can easily swivel the 
fitting without resistance, the fitting is not tightened enough. It 
may feel like you can’t tighten it anymore and it just keeps 
spinning but if you use a gripping tool (multi grips) to grab the 
collar of the fitting and use your hand to hold the valve itself 
steady, you will be able to further tighten the valve. The valve 
is tight enough when you feel light to moderate resistance 
when trying to swivel the valve. 
3. If you screw the valve on and the collar ‘bottom’s out’ on the 
tap, you may need to add another washer (to bulk up the 
space). 

The unit is not 
producing any 
water? 

1. Water Supply is 
off or 
disconnected. 
 
2. Pre-Filter has a 
blockage 
 
3. Insufficient 
Water Pressure 
 
4. Water Quality 

1. Turn on the water supply and ensure there are no 
obstructions to the water flow. 
2. Disconnect the tube between the membrane and pre-filters 
and run water at full pressure to see if water comes out of the 
filter. – If the water does not come out (or is very weak 
pressure) the filter may need to be changed. 
3. Reverse Osmosis required 50psi (Minimum) to operate – 
70psi+ is ideal. If you have lower than 50psi pressure this unit 
may not be suitable for you. 
4. Ensure that the water quality meets the feed water 
requirements outlined previously. High levels of impurity such 
as hardness and salt can cause the system to block or not 
produce water. 

I am getting much 
more waste water 
than filtered water 

1. Water Pressure 
 
 
2. Water Quality 
 
 
3. Blockage 

1. Our units are designed to run at approx. 1:2 – 1:3 waste 
water ratio at 70 psi. If your pressure is lower than 70 psi, the 
production rate may decrease and cause more drain water 
than filtered water. 
2. If your inlet water quality is poor and contains higher salts 
and hardness the filter may produce less water than the 
specified amount. 
3. If you have good pressure, and average water quality it is 
possible there is a small blockage somewhere in the system. 
Try to follow the water flow along the system, disconnecting 1 
tube at a time to try and pinpoint where the water is ‘stopping’ 

High pH Reading 

1. Alkaline Filter 
 
 
2. GAC Filter 
 
 
3. Insufficient 
Testing Equipment 

1. Alkaline Filters are designed to increase the pH of the water. 
When the filter is new it will be high but will soon settle to the 
advertised levels after adequate flushing. 
2. If you have a post GAC filter (Carbon), this will naturally 
increase the pH of the water. pH is the measure of Hydrogen 
in the water and this hydrogen will vent off the water if you 
leave it to stand and the pH will then drop back down to the 
normal level. 

Summary of Contents for H1-EQ5AN

Page 1: ...onnection 3 II Drain Clamp 3 III Drilling Faucet Hole Stainless Steel Sink 3 IV Mounting the Faucet 3 4 V Storage Tank Assembly 4 Connecting the RO System 4 I Fittings 4 II Tubing 4 System Start Up Operation 5 I Plumber Commissioning Steps 5 II Client to Complete Commissioning 5 III Automatic Shut off 6 IV Turning the System On Off 6 Maintenance 6 I Replacement Parts 6 II Replacement Cartridges 6 ...

Page 2: ...rease If you are not able to supply 500 kPa to the system it is suggested to purchase the H1 302BN system and select the booster pump option III Before You Begin Installation All components that come pre assembled will need to be thoroughly checked before installation Due to transit fittings and other components may be loosened or unseated ensure fittings tubing and filters are inspected before co...

Page 3: ...nly 2 Unscrew the clamp and wrap it around the pipe loosely screw it back up leaving enough slack so you can position the hole with the outlet of the clamp 3 Tighten the clamp to create a seal III Drilling Faucet Hole Stainless Steel Sink 1 Drilling through a stainless steel sink can be achieved by marking the location with a centre punch and drilling a 3 16 Pilot Hole When drilling through stainl...

Page 4: ...ittings On the back of the unit you will find the connection points If required there are 4x Stem elbow fittings you can install into these ports to provide better angle for tubing installation II Tubing It is best to allow enough excess tubing to be able to easily move the system out from the cupboard when maintenance is required Measure a length of white tubing Inlet Tubing to be installed betwe...

Page 5: ...his should trigger the systems automatic shut off within 1 minute Water should stop flowing If the water does not shut off within 60 seconds it could be due to an air lock in the shut off valve which is common for new installs 7 Open the tank valve so the tank can begin filling The tank will take up to 2 hours to fill depending on several factors II Client to Complete Commissioning Note for Plumbe...

Page 6: ... when you replace the filters you are essentially replacing both the housing and the filter Due to this you essentially have a new system every time you replace filters The only remaining parts are the fittings and tubing which are replaced periodically as stated above Cartridges have a varying life span but generally can be replaced under the following guidelines under normal working conditions S...

Page 7: ...there are no obstructions to the water flow 2 Disconnect the tube between the membrane and pre filters and run water at full pressure to see if water comes out of the filter If the water does not come out or is very weak pressure the filter may need to be changed 3 Reverse Osmosis required 50psi Minimum to operate 70psi is ideal If you have lower than 50psi pressure this unit may not be suitable f...

Page 8: ...ters will naturally increase the TDS of the water especially when new If you have low TDS water already it is possible for the TDS level out of the alkaline filter to be higher than your inlet water This is because you are adding minerals back into the water therefore increasing the TDS and alkalinity 3 If the filters have not been changed as per the recommendations it is likely that the increased...

Page 9: ...ctuate due to several factors but mostly due to inlet pressure Note that as the EC TDS of the water reduces so does the accuracy of most TDS EC monitors and meters Also rejection rate will also be lower if your incoming TDS is already for example 50 TDS 2 As mentioned online and in the manual the optimal working pressure for this system is 70psi 500 kPa At 70psi or above you will achieve the best ...

Page 10: ...s been absorbed the lever will snap shut stopping the inlet water flow and saving any possible water damage Best results when Plastic outer cover REMOVED The Shut off valve should be connected between the FWV and the Filter System inlet This system is certified to WaterMark Standards AS NZS 3497 Under Certificate number 022780 WaterMark certification is the level of certification required by law f...

Page 11: ...e contact them to facilitate the warranty on your behalf All replaced or exchanged parts become the property of HPF HPF does not cover the workmanship of the plumber who originally installed the system Responsibility for damages that occur during installation fall with the plumber Qualification for Warranty As per Australian Plumbing Codes all filter systems must be installed by a qualified plumbe...

Page 12: ...2 email info hpfiltration com au This warranty is provided in addition to other rights and remedies you have under law Our products come with guarantees which cannot be excluded under the Consumer Guarantees Act Extended Warranty The H1 302BN H1 EQ5AN Undersink RO System is eligible for an extended 4 year warranty commencing no later than 12 months from sale date to provide a total warranty of 5 y...

Reviews: