FSA GT1-12LS Manual Download Page 2

Technical Overview 

I. Important Notes 

For correct operation of this appliance, it is essential to observe the manufacturer’s instructions. 

If this system is to be installed permanently as a POU or POE system, 
installation must be carried out by a qualified plumber or authorised technician to 
comply with Australian Plumbing Codes. 

This system contains electrical 

components and plumbing components; Use caution and if leaking occurs, 
turn the power off immediately before conducting maintenance or repair to 
the system. 

This appliance is not intended for use by persons (including children) with 
reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety.  

Children should be supervised to ensure that they do not play with the appliance.  

If the supply cord is damaged, it must be replaced by a special cord or assembly 
available from the manufacturer or its service agent. 

II. Before You Purchase/Open 

The system requires specific working conditions to be met before installation, some general guidelines* are 
listed below. If these conditions are not met, the system may not be suitable for the application and may not 
function as specified. 

These systems are designed for filtration on mains water for the removal of minerals, salts and other 
impurities. The system may also be used on other sources such as Bore Water however you should 
enquire with the supplier before purchasing for any use other than mains water to ensure the system is 
correct you the application. 

 

 

 

 

 

 

 

III. Space Requirements 

The LSRO Systems are not IP rated and therefore are not suitable for external installation without adequate 
weatherproofing or cover from the elements including but not limited to Rain/Moisture & Frost. 
The Frame of the system includes mounting holes so the system can be mounded to a wall. It is 
recommended that the system be mounted if possible, rather than free-standing as this will help support the 
weight of the system when full of water. If necessary, the system is able to also free stand. 

System Dimensions 

Depth: 26cm 
Width: 44 cm 
Height: 85cm 

If the system is to be enclosed in a cover, allow adequate ventilation around the pumps & power supplies to 
prevent overheating. 

Feed Water Conditions 
*Guideline only* 

Min 

Max 

Inlet Pressure 

350 kPa 

700 kPa 

Temperature 

0.5°C 

38°C 

pH Level 

11 

TDS 

0 mg/L 

2,000 mg/L 

Iron 

0 mg/L 

0.3 mg/L 

Manganese 

0 mg/L 

0.1 mg/L 

Hardness 

0 mg/L 

200 mg/L

 

Summary of Contents for GT1-12LS

Page 1: ...ion Introduction 4 I Site Preparation 4 II Installation Mounting 4 III Installation Free Standing 4 IV Installing Connections Quick Connect 4 V Filter Protection 5 VI Drain Waste 5 VII Cartridge Insta...

Page 2: ...ed below If these conditions are not met the system may not be suitable for the application and may not function as specified These systems are designed for filtration on mains water for the removal o...

Page 3: ...s which may require treating before the system Bore Water filtration is used when the water meets specific conditions where an RO unit will be suitable to remove elevated salt levels in the water gene...

Page 4: ...tem to reduce negative effects on the pressure flow and performance of the system It is also recommended that the process water filtered water does not have to travel more than 2m elevation above the...

Page 5: ...ted Before Spun Spun Before Carbon Highest Micron Before Lowest Micron As an example a common filter set would be 5uM Polyspun 20uM Low Pressure Carbon 0 5uM Chloramine Reduction Carbon You would inst...

Page 6: ...straight cut with no rough edges Measure a length of tubing from the drain valve located behind the pumps which is marked as to drain or Flow 2000 to a suitable drainage point Measure a length of tubi...

Page 7: ...s the filters are classed as a consumable item III Automation The system is fitted with high and low pressure switches This will allow the system to know when to shut off due to the tank being full or...

Page 8: ...arbon Block 6 12 Months RO Membranes GT13 37 ALP Asprinn Reverse Osmosis Membrane 100GPD TDS Checking Required 4 pc Required 1 3 Years Post Filters GT6 7C 5 Micron inline GAC 2 5 5 000L 6 Months GT6 2...

Page 9: ...ing pH levels in lower EC water i e The guy at the pool shop is not going to cut it We have access to high quality testing equipment and frequently test our units and conduct research If you feel that...

Page 10: ...pump may require replacing if it has been overworked outside the manufacturer s guidelines 2 Power surges may cause the power supply to short out Other things include water leaking or overheating An...

Page 11: ...of of installation in the form of an invoice and or receipt Filter systems must be maintained as per FSA recommendations including the use of replacement filters fittings and components supplied by FS...

Page 12: ...f the system is installed on an open circuit a plumber may not be required in this case the system must be installed in accordance with the user manual and determined to be correctly installed by FSA...

Reviews: