M6500 Series NE Configuration Manual
155
Figure9-28 OCh Monitoring Data When Mismatched
9.2.3. FEC Current Performance Statistics
9.2.3.1. FEC Monitoring Parameters Introduction
As shown in the figure, the monitoring parameters of FEC monitoring points include maximum error correction
rate, maximum error correction rate time stamp, average error correction rate, suspicious interval marker,
running time and reset operation. The performance parameters of FEC will be enabled or disabled at the same
time.
Figure9-29 FEC Monitoring Parameters
9.2.3.2. View FEC Monitoring Information
As shown in the figure, select the appropriate network elements, slots, ports and monitoring cycle through the
selection box above the menu, the FEC value of a certain network element/slot/port will be displayed. There is
only one entrance-near end monitoring point for FEC. Optical module is inserted into the monitoring port. FEC
data and corresponding generation time stamp which are currently read will be displayed. After the port is
enabled, the suspicious interval marker should be untrustworthy. The running time counts from 0. After 900
seconds, the suspicious interval marker will become trustworthy and the running time counts again from 0. The
last 15-minute data automatically becomes the history data.
Figure9-30 15-Minute Monitoring Data of FEC
Optical module is inserted into the monitoring port. FEC data and corresponding generation time stamp which
are currently read will be displayed. After the 24-hour performance monitoring port is enabled, the suspicious
interval marker should be untrustworthy. The running time counts from 0. After 86400 seconds, the suspicious
interval marker will become trustworthy and the running time counts again from 0. The last 24-hour data
automatically becomes the history data, as shown in the figure below:
Summary of Contents for M6500 Series
Page 12: ...M6500 Series NE Configuration Manual 11 Figure 1 3 Start NMS Server...
Page 109: ...M6500 Series NE Configuration Manual 108 Figure6 5 TP Multiplexing Configuration Step 2...
Page 113: ...M6500 Series NE Configuration Manual 112 Figure6 12 Set Line Side PM Overhead...
Page 116: ...M6500 Series NE Configuration Manual 115 Figure6 16 Configure Line Side Port TTI...
Page 117: ...M6500 Series NE Configuration Manual 116 Figure6 17 Configure Client Side Local End Port TTI...
Page 129: ...M6500 Series NE Configuration Manual 128 Figure7 10 Select Protection Mode...