YPF95LP SERIES PORTABLE FILTRATION SYSTEMS 

CHAPTER 3:  FILTER PREPARATION 

 

 

3-1 

3.1  Assembling The Filter System 

 

On initial installation and before each use, remove all loose parts from the filter, wash the filter pan 
and all accessories in hot, soapy water and dry thoroughly.

 

 
 

 

WARNING! 

Water or boil-out solution 

MUST

 not be allowed to drain into the filter pan or filter 

system.  Irreversible damage will result if water is allowed into the system, and the 

warranty will be voided. 

 

 
YPF95 Series portable filtration systems use a filter support grid, one sheet of filter paper and a 
hold-down ring to secure the filter paper in place.  

 

 

See illustration for proper assembly.

 

 
1.

 

Filter Pan Cover Front 

2.

 

Filter Pan Cover Rear 

3.

 

Hold-Down Ring  

4.

 

Filter Paper (one sheet) 

5.

 

Screen/Sana Grid 

6.

 

Filter Pan Assembly 

 
  
 

A.

 

First, place the Sana Grid in the bottom of filter pan. 

 

B.

 

Place one sheet of filter paper on top of the Sana Grid.  Ensure the paper evenly covers the filter 
pan bottom. 

 
C.

 

Position the hold-down ring on top of the filter paper securely against the filter pan bottom, 
forming a tight seal.  

 

D.

 

Sprinkle 8 ounces of filter powder over the filter paper, distributing the powder as evenly as 
possible.  If filtering a second frypot immediately after the first, add only 4 ounces of filter 
powder for the second filtering. 

 

E.

 

Place filter pan covers onto the filter pan assembly. 

 
F.

 

Position filter in the space between the two fryers.  Lock the rear casters to prevent filter from 
moving out of position during the filtering process. 

5

4

3

2

1

6

Summary of Contents for YPF95 Series

Page 1: ...the Commercial Food Equipment Service Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 JUNE 2007 8196325 YPF95 Series Portable Filtration Systems Install...

Page 2: ...plug for your protection against shock hazard and should be plugged directly into a properly grounded three hole receptacle Do not cut off remove or otherwise bypass the grounding prong on this plug I...

Page 3: ...te operational cleaning and technical procedures and may not conform to on site management operational procedures NOTICE IF DURING THE WARRANTY PERIOD THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMEN...

Page 4: ...Systems Installation Operation Manual TABLE OF CONTENTS Page 1 INTRODUCTION 1 1 2 IMPORTANT INFORMATION 2 1 3 INSTALLATION INSTRUCTIONS 3 1 4 FILTER OPERATION 4 1 5 CLEANING AND MAINTENANCE 5 1 6 TROU...

Page 5: ...following information is required Model Number Type Serial Number Optional Features Item Part Number Quantity Needed 1 2 Service Information Call the 1 800 551 8633 or 318 865 1711 Service Hotline nu...

Page 6: ...roughly Throughout this manual you will find notations enclosed in double bordered boxes similar to the ones below CAUTION CAUTION boxes contain information about actions or conditions that may cause...

Page 7: ...through a representative Qualified personnel must be experienced in such work be familiar with all electrical precautions involved and have complied with all requirements of applicable national and l...

Page 8: ...l as other manufacturers equipment Oil capacity is approximately 105 pounds Unit specifications are listed below Model Unit Height inches Unit Width inches Unit Length inches Tank Height inches Oil Ca...

Page 9: ...oil filtration and draining cleaning procedures An ON OFF switch activates deactivates the filter pump and a 7 amp 120V or 5 amp 230V circuit breaker switches the power OFF if an overload occurs An i...

Page 10: ...essories they will be needed for filter setup and operation Any accessories or starter kits included with the unit will be packaged inside the filter tank After unpacking immediately check the equipme...

Page 11: ...1 Filter Pan Cover Front 2 Filter Pan Cover Rear 3 Hold Down Ring 4 Filter Paper one sheet 5 Screen Sana Grid 6 Filter Pan Assembly A First place the Sana Grid in the bottom of filter pan B Place one...

Page 12: ...ter pan and will prevent splashing during filtration 4 1 2 3 4 1 Oil Baffle remove front lid 2 Filter Pan Cover Rear 3 Filter Pan 4 Drain Tube fryer to filter YPF95 portable filter positioned correctl...

Page 13: ...e primarily as an independent filter unit Operations always start by ensuring the unit is properly plugged in and situated in the filter space between the fryers The general layout of a YPF95 Series p...

Page 14: ...e crumb tray if equipped in portable filter systems must be emptied into a fireproof container at the end of frying operations each day Some food particles can spontaneously combust if left soaking in...

Page 15: ...down ring in the filter pan on top of the filter paper 8 Measure 8 ounces of filter powder and distribute evenly over the surface of the paper 9 Replace the filter pan covers and slide it back into pl...

Page 16: ...ottom of the frypot before closing the drain valve NOTE The oil return wand can also be mounted in the wand holster inside the pan for extended filtering periods polishing prior to refilling frypot NE...

Page 17: ...unless cooking oil is at operating temperature 5 2 Each Filter Use Each time the portable filter is used Wash down the insides of the filter pan with hot oil during the filtering process DO NOT allow...

Page 18: ...the filter unit and ensure that they are properly tightened DANGER The crumb tray if applicable in portable filter systems must be emptied into a fireproof container at the end of frying operations e...

Page 19: ...bris The first indication of paper plugging is a slow oil flow return rate and a surging jerking in the filter unit To correct this review the instructions for the correct use of filter powder and cha...

Page 20: ...ty pan Verify filter paper is clean and properly installed Refill pan and restart process Pump starts and abruptly stops Reset circuit breaker Pump is blocked or wiring is loose Call FASC for service...

Page 21: ...witch Housing 120 230 VAC 50 60 Hz Motor w Thermal Overload Protector Electrical Junction Box C NC Thermal Overload Reset Switch T4 T5 T2 P1 P2 T3 T8 6 3 2 YPF95 230V Wiring BLK BRN GRN YEL BLU 5 Amp...

Page 22: ...YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 7 PARTS LIST 7 1 7 Main Components...

Page 23: ...809 0191 Washer Spring Lock 3 106 4610 Rear Panel Filter 4 106 4613 Cover Assembly Top of Arm 5 106 4647 Plumbing Oil Return 6 106 8342 Filter Pan Cover Front 7 200 8887 Cover Filter Plug 8 210 8733 H...

Page 24: ...e Filter Pan 32 810 2957 Tubing Faucet Over the Top 33 813 0006 Bushing Hex to 3 8 NPT Black Metal 34 813 0022 Nipple x Close NPT Black Metal 35 813 0062 Elbow 1 2 90 Black Metal 36 813 0093 Nipple x...

Page 25: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 26: ...hreveport Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES SER...

Reviews: