![Frymaster PF50 Series Operating Manual Download Page 19](http://html1.mh-extra.com/html/frymaster/pf50-series/pf50-series_operating-manual_2340620019.webp)
PF50 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 6: TROUBLESHOOTING
6-2
6.2 General Troubleshooting (cont.)
Pump won't
start.
·
Tripped thermal overload switch.
·
Incorrect or no line voltage.
Pump stops
during filtering
process.
·
Allow filter unit to cool for at least 45 minutes and
then press (reset) the motor thermal overload
switch.
·
Turn filter pump "OFF". Allow oil to cool then empty
pan. Verify filter paper is clean and properly
installed. Refill pan and restart process.
Pump starts
and abruptly
stops.
·
Reset thermal overload switch.
·
Pump is blocked or wiring is loose. Call FAS for
service.
·
Motor failed; call FAS for service.
Pumping is
erratic.
·
Verify that filter paper is properly installed under
hold-down ring.
·
Verify that filter hose connection is tight and secure.
Oil not being
returned to
frypot.
·
The filter hose is clogged with debris. Clear hose.
·
Clogged filter paper. Scrape off excess sediment or
replace filter paper.
·
Filter pan suction tube is blocked. Use a thin,
flexible wire to unclog.