![Frymaster FPH17SC Series Installation, Operation & Service Manual Download Page 23](http://html1.mh-extra.com/html/frymaster/fph17sc-series/fph17sc-series_installation-operation-and-service-manual_2340504023.webp)
5–4
5.3
Annual/Periodic System Inspection
This appliance should be inspected and adjusted periodically by qualified service personnel as
part of the galley material maintenance management (3M) program.
Frymaster recommends that a Factory Authorized Service Technician inspect this appliance at
least annually as follows:
Fryer
•
Inspect the cabinet inside and out, front and rear for excessive oil build-up and/or oil migration.
•
Verify that the heating element wires are in good condition and that leads have no visible fraying
or insulation damage and that they are free of oil migration build-up.
•
Verify that heating elements are in good condition with no carbon/caramelized oil build-up.
Inspect the elements for signs of extensive dry-firing.
•
Verify that the tilt mechanism is working properly when lifting and lowering elements, and that
the element wires are not binding and/or chafing.
•
Verify the heating-element amp-draw is within the allowed range as indicated on the appliance’s
rating plate.
•
Verify that the temperature and high-limit probes are properly connected, tightened and
functioning properly, and that mounting hardware and probe guards are present and properly
installed.
•
Verify that component box and contactor box components (i.e. controller, relays, interface
boards, transformers, contactors, etc.) are in good condition and free from oil migration build-up
and other debris.
•
Verify that component box and contactor box wiring connections are tight and that wiring is in
good condition.
•
Verify that all safety features (i.e. contactor shields, drain safety switches, reset switches, etc.)
are present and functioning properly.
•
Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in
serviceable condition.
•
Verify that all wiring harnesses and wiring connections are tight and in good condition.
Built-In Filtration System
•
Inspect all oil-return and drain lines for leaks and verify that all connections are tight.
•
Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the
crumb basket, instruct the work center supervisor/watch supervisor that the crumb basket must
be emptied into a fireproof container and cleaned daily.