3-4
Right Viewing Ports
Left Viewing Ports are
behind the motor
housings.
The optimum burn is a bright orange-red glow. If a blue flame is observed, or if there are dark spots
on a burner face, adjust the air gas mixture as follows: On the side of the blower housing opposite
the motor is a plate with a locking nut. Loosen the nut enough to allow the plate to be moved, then
adjust the position of the plate to open or close the air intake opening until a bright orange-red glow
is obtained. Carefully hold the plate in position and tighten the locking nut.
3.3
Shutting the Fryer Down
For short-term shut down during the workday, place the controller ON/OFF switch in the
OFF
position and put the frypot covers in place (if the fryer is so equipped).
When shutting the fryers down at closing time, filter the oil and clean the fryers. Place the controller
ON/OFF switch in the
OFF
position. For long-term shutdowns, see below:
Put the frypot covers in place (if the fryer is so equipped).