![Frymaster FOOTPRINT RE80 Series Service & Parts Manual Download Page 10](http://html1.mh-extra.com/html/frymaster/footprint-re80-series/footprint-re80-series_service-and-parts-manual_2340494010.webp)
1-5
2.
On dual-vat fryers, and on full-vat fryers where the temperature probe is attached to the element
being replaced, disconnect the wire harness containing the probe wiring. Using a pin pusher,
disconnect the probe wires from the 12-pin connector C-6.
3.
Remove screws holding element wiring cover in place and remove cover.
4.
In the rear of the fryer directly behind the frypot disconnect the 6-pin connector for the left
element (as viewed from the front of the fryer) or the 9-pin connector for the right element.
Press in on the tabs on each side of the connector while pulling outward on the free end to extend
the connector and release the element leads (see photo below). Pull the leads out of the
connector and out of the wire sleeving.
5.
Raise the element to the full up position and support the elements.
6.
Remove the hex head screws and nuts that secure the element to the tube assembly and pull the
element out of the frypot.
NOTE:
Full-vat elements consist of two dual-vat elements clamped
together. For full-vat units, remove the element clamps before removing the nuts and screws that
secure the element to the tube assembly.
7.
If applicable, recover the probe bracket and probe from the element being replaced and install
them on the replacement element. Install the replacement element in the frypot, securing it with
the nuts and screws removed in Step 5 to the tube assembly. Ensure the gasket is between the
tube and element assembly.
8.
Route the element leads through the element tube assembly and into the wire sleeving to prevent
chafing. Ensure that the wire sleeving is routed back through the Heyco bushing keeping it clear
from the lift springs. Also ensure that the wire sleeving extends into the tube assembly to
prevent the edge of the tube assembly from chafing the wires. Press the pins into the connector
in accordance with the diagram on the following page, and then close the connector to lock the
leads in place.
NOTE:
It is critical that the wires be routed through the sleeving to prevent
chafing.
Summary of Contents for FOOTPRINT RE80 Series
Page 21: ...1 16 1 13 Wiring Diagrams 1 13 1 Basket Lift...
Page 22: ...1 17 1 13 2 PBI Basket Lift...
Page 23: ...1 18 1 13 3 Standard Component Wiring...
Page 24: ...1 19 1 13 4 KFC1 and CM4S Component Wiring...
Page 25: ...1 20 1 13 5 Component Wiring Single Phase 805 1786...
Page 26: ...1 21 1 13 6 Component Wiring 480V Non Filter 805 1776...
Page 27: ...1 22 1 13 7 Component Wiring Fast Ready...
Page 28: ...1 23 1 13 8 Component Wiring KFC INDIA K3000...
Page 29: ...1 24 1 13 9 Component Wiring KFC INDIA FAST...
Page 30: ...1 25 1 13 10 Contactor Box Domestic 17 kW 1 13 11 Contactor Box Domestic 21 kW...
Page 31: ...1 26 1 13 12 Contactor Box Export 17kW and 21kW...
Page 47: ...2 15 2 5 Oil Return System Components 20 1 2 3 9 7 10 6 8 11 5 4 12 18 15 13 19 14 16...
Page 57: ...2 25 2 9 Electronics and Wiring Components 2 9 1 Component Boxes...
Page 59: ...2 27 2 9 2 Contactor Boxes...