background image

 

 DANGER 

Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any 

other appliance. 

 

 DANGER 

The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container 

at the end of frying operations each day. Some food particles can spontaneously combust if left 
soaking in certain shortening material.  Additional information can be obtained in the filtration 
manual included with the system. 

 

 WARNING 

Do not bang fry baskets or other utensils on the fryer’s joiner strip.  The strip is present to seal 
the joint between the fry vessels.  Banging fry baskets on the strip to dislodge shortening will 
distort the strip, adversely affecting its fit.  It is designed for a tight fit and should only be 
removed for cleaning. 

 

NOTICE 

All fryers shipped without factory supplied cords and plug assemblies must be hardwired using 
flexible conduit to the terminal block located on the rear of the fryer.  These fryers should be 
wired to NEC specifications.  Hardwired units must include installation of restraint devices. 

 

 DANGER 

Single fryers equipped with legs must be stabilized by installing anchor straps.  All fryers 
equipped with casters must be stabilized by installing restraining chains 

 

 DANGER 

Adequate means must be provided to limit the movement of this appliance without depending on 
or transmitting stress to the electrical conduit.  A restraint kit is provided with the fryer.  If the 
restraint kit is missing contact your local Frymaster Factory Authorized Service Center (FASC) 
for part number 826-0900. 

 

 DANGER 

This fryer may have two power cords and prior to movement, testing, maintenance and any 
repair on your Frymaster fryer; disconnect BOTH electrical power cords from the electrical 
power supply.     

 

 
 

 

Summary of Contents for FOOTPRINT 8195915

Page 1: ...r of the Commercial Food Equipment Service Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 JANUARY 2005 8195915 PRO SERIES ELECTRIC FRYERS Installation...

Page 2: ...of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the U S Food and Drug Administration NOTICE Drawings and photos used in this manual a...

Page 3: ...TICE All fryers shipped without factory supplied cords and plug assemblies must be hardwired using flexible conduit to the terminal block located on the rear of the fryer These fryers should be wired...

Page 4: ...1 Draining and Manual Filtering 4 1 4 2 Preparing the Built In Filtration System for Use 4 2 4 3 Operation of the Filter 4 5 4 4 Disassembly and Reassembly of the Magnasol Filter 4 8 4 5 Draining and...

Page 5: ...empting to operate your unit read the instructions in this manual thoroughly Throughout this manual you will find notations enclosed in double bordered boxes similar to the one below DANGER Hot cookin...

Page 6: ...ns Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 1 4 Euro...

Page 7: ...r Technical Services Department 1 800 24FRYER The following information will be needed in order to assist you efficiently Model Number _________________________ Serial Number _________________________...

Page 8: ...ng a temperature rating of not less than 167 F 75 C NOTICE If the electrical power supply cord is damaged it must be replaced by a Frymaster Dean Factory Authorized Service Center technician or a simi...

Page 9: ...o combustible construction A minimum of 24 inches 61cm should be provided at the front of the equipment for servicing and proper operation In Australia To be installed in accordance with AS 5601 AG 60...

Page 10: ...ing stress to the electrical conduit A restraint kit is provided with the fryer If the restraint kit is missing contact your local Frymaster Factory Authorized Service Center FASC for part number 826...

Page 11: ...ces oil must be removed from the fryer before attempting to move it to avoid oil spills falls and severe burns This fryer may tip and cause personal injury if not secured in a stationary position 1 Cl...

Page 12: ...t Lower the elements and then pack the shortening around and over the elements It may be necessary to add shortening to bring the level up to the proper mark after the packed shortening has melted DAN...

Page 13: ...and clean the fryers See Chapters 4 and 5 3 Place the frypot covers on the frypots 3 2 Controllers This fryer may be equipped with any of the following controllers Computer Magic III CM III Basket Li...

Page 14: ...er to the frypot Boil Out Procedure on Page 5 2 Refer to the separate Frymaster Fryer Controllers User s Manual furnished with your fryer for the specific controller operating instructions Refer to Ch...

Page 15: ...of hot oil shortening DANGER When draining oil shortening into a disposal unit or portable filter unit do not fill above the maximum fill line located on the container If your fryer is not equipped wi...

Page 16: ...down into the bottom of the frypot DO NOT operate the fryer with a solid block of shortening sitting in the upper portion of the frypot This will cause damage to the frypot and may cause a flash fire...

Page 17: ...ccess or to allow a shortening disposal unit SDU to be positioned under the drain 2 Inspect the filter pan connection fitting to ensure that both O rings are in good condition See Figure 2 3 Then in r...

Page 18: ...awer The pan may be removed for cleaning or to gain access to interior components by lifting the front of the pan to disengage the front rollers then pulling it forward until the rear rollers clear th...

Page 19: ...ltering cooking oil or shortening DANGER NEVER attempt to drain cooking oil or shortening from the fryer with the burners lit Doing so will cause irreparable damage to the frypot and may cause a flash...

Page 20: ...ined from the frypot turn the filter handle to the ON position to start the pump and begin the filtering process There may be a slight delay before the pump activates 4 The filter pump draws the cooki...

Page 21: ...osed the fryer will not operate Turn the fryer ON and allow the cooking oil shortening to reach setpoint DANGER The crumb tray in fryers equipped with a filter system must be emptied into a fireproof...

Page 22: ...e pieces can be cleaned with the edge of a Scotch Brite or similar cleaning pad 2 At each scheduled boil out disassemble the leaf filter assembly and place in the frypot being boiled out Follow the bo...

Page 23: ...2004 the filter pan cover on must be removed to allow the unit to be positioned beneath the drain To remove the lid lift up on the front edge and pull it straight out of the cabinet Refer to the docum...

Page 24: ...the fryer cabinet with a dry clean cloth Wipe all accessible metal surfaces and components to remove accumulated oil shortening and dust Clean outside the fryer cabinet with a clean damp cloth soaked...

Page 25: ...d Also after the fryer has been in use for a period of time a hard film of caramelized vegetable oil will form on the inside of the frypot This film should be periodically removed by following the boi...

Page 26: ...with cooking oil shortening DANGER Remove all drops of water from the frypot before filling with cooking oil or shortening Failure to do so will cause spattering of hot liquid when the oil or shorteni...

Page 27: ...Verify that the temperature and high limit probes are properly connected tightened and functioning properly and that mounting hardware and probe guards are present and properly installed Verify that...

Page 28: ...rn handles in the OFF position Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches No air bubbles should be v...

Page 29: ...s taking steps to ensure that it doesn t happen again If a controller malfunctions because of a poor connection check all other connections too If a fuse continues to blow find out why Always keep in...

Page 30: ...ailed is beyond the scope of operator troubleshooting Call FASC Controller won t activate A Drain valve is open A This fryer is equipped with a drain safety switch which prevents the heating element e...

Page 31: ...cycle can be cancelled or bypassed Refer to the separate Frymaster Fryer Controllers User s Manual for the procedure for canceling the melt cycle for the particular controller installed on your fryer...

Page 32: ...es 395 F 202 C This in an indication of a malfunction in the temperature control circuitry including a failure of the high limit thermostat Shut the fryer down immediately and call FASC Basket lift ti...

Page 33: ...on and may appear for a short while if a large batch of frozen product is added to the frypot If the display never goes out the fryer is not heating Look for a decimal in the LED display between digit...

Page 34: ...fryer down immediately and call FASC Digital controller display shows Problem with the temperature measuring circuitry including the probe This indicates a problem within the temperature measuring ci...

Page 35: ...r pump won t start C Blockage in filter pump Test Close the drain valve and pull the filter pan out from the fryer Activate the pump If the pump motor hums for a short time then stops the probable cau...

Page 36: ...at or near 350 F 177 C At temperatures lower than this the oil shortening becomes too thick to pass through the filter medium easily resulting in much slower oil return and eventual overheating of the...

Page 37: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 38: ...Shreveport Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 688 2200 Tech Support 1 318 219 7135 819 5915 PRINTED IN THE UNITED STAT...