MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-15
1.8.9 Replacing Burner Ceramic Targets
DANGER
Drain the frypot or remove the handle from the drain valve before proceeding further.
1.
Disconnect fryer from electrical and gas supplies.
2.
On FMCF fryers, remove square-drain sections as necessary to expose burner.
3.
Disconnect the wires from the gas valve terminal block, marking each wire to facilitate
connections.
4.
Remove the high-limit thermostat wires from the gas valve pilot coil.
5.
Disconnect the pipe union collar at the left side of the gas valve (arrow).
6.
Remove front burner shields to access burner assembly.
7.
Remove the burner heat shield hanger screws at the front of the burner and remove the heat
shield.
8.
Remove the burner hanger screws and lower the front of the main burner. Pull it forward to clear
the rear burner hanger, and then lower the burner to the floor.
9.
Raise the front of the fryer enough to slide the burner from under the fryer cabinet.
Disconnect union (arrow) to remove burner manifold assembly.