Frymaster BIPH55 Series Operator'S Manual Download Page 7

1-2 

1.2 Safety 

Information 

 
Before attempting to operate your unit, read the instructions in this manual thoroughly.  Throughout 
this manual, you will find notations enclosed in double-bordered boxes similar to the ones that 
follow. 
 

 CAUTION 

CAUTION

 

boxes contain information about actions or conditions that

 may cause or result 

in a malfunction of your system

 

 WARNING 

WARNING

 

boxes contain information about actions or conditions that 

may cause or result 

in damage to your system

, and which may cause your system to malfunction. 

 

 

DANGER 

DANGER

 

boxes contain information about actions or conditions that 

may cause or result 

in injury to personnel

, and which may cause damage to your system and/or cause your 

system to malfunction.

 

 
Your fryer is equipped with automatic safety features: 
 
1.  High temperature detection shuts off gas to the burner assembly should the controlling 

thermostat fail. 

 
2.

 

A safety switch built into the drain valve on units with filter systems prevents burner ignition 
with the drain valve even partially open. 

 

1.3 

Computer Information for the M2000 Computers 

FCC COMPLIANCE 
 

This equipment has been tested and found to comply with the limits for a Class A digital device, pur-
suant to Part 15 of the FCC rules.  While this device is a verified Class A device, it has been shown 
to meet the Class B limits.  These limits are designed to provide reasonable protection against harm-
ful interference when the equipment is operated in a commercial environment.  This equipment 
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance 
with the instruction manual, may cause harmful interference to radio communications.   
Operation of the equipment in a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own expense. 
 
The user is cautioned that any changes or modifications not expressly approved by the party respon-
sible for compliance could void the user's authority to operate the equipment. 
 
If necessary, the user should consult the dealer or an experienced radio and television technician for 
additional suggestions. 

Summary of Contents for BIPH55 Series

Page 1: ...Shreveport Louisiana 71135 1000 TEL 318 865 1711 FAX Parts 318 219 7140 Tech Support 318 219 7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE OCTOBER 2005 1 800 24 FRYER www frymaster com Email servi...

Page 2: ...basic plumbing code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the U S Food and Drug Administration NOTICE Drawings and photos...

Page 3: ...or other reproductive harm Operation installation and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers crystalline silica and or carbon monoxide Inhalat...

Page 4: ...pot replacement Components that are not part of the frypot assembly such as the blower gas valve micro switches doors and cabinetry are not covered by the frypot warranty If the frypot is found to be...

Page 5: ...ANTY EXCLUSIONS This warranty does not cover equipment that has been damaged due to misuse abuse alteration or accident such as improper or unauthorized repair including any frypot which is welded in...

Page 6: ...nd can be purchased as single units or in batteries of up to five fryers Pro Series H55 high efficiency gas fryers employ a unique infrared burner system that uses up to 43 less energy to cook the sam...

Page 7: ...er ignition with the drain valve even partially open 1 3 Computer Information for the M2000 Computers FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A di...

Page 8: ...ersonnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions or who have had previous experience with the operation of the eq...

Page 9: ...ntainer is retained for inspection Frymaster DOES NOT ASSUME RESPONSIBILITY FOR DAMAGE OR LOSS INCURRED IN TRANSIT 1 8 Parts Ordering and Service Information For non routine maintenance or repairs or...

Page 10: ...5 1711 When requesting service please have the following information ready Model Number Serial Number Type of Gas In addition to the model number serial number and type of gas please be prepared to de...

Page 11: ...ons installation and operation shall comply with the codes or regula tions in force in the country in which the equipment is installed DANGER Building codes prohibit a fryer with its open tank of hot...

Page 12: ...a drip tray beneath the lowest edge of the filter For U S installation NFPA standard No 96 states A minimum distance of 18 in 450 mm should be maintained between the flue outlet and the lower edge of...

Page 13: ...pon the specific configuration ordered your fryer may have been shipped without installed casters DO NOT INSTALL THIS APPLIANCE WITHOUT CASTERS If the appliance requires the installation of casters in...

Page 14: ...indicates OFF If the store is equipped with a hood interlock system the hood exhaust fan should be on If not the store hood interlock system is improperly wired and must be corrected c Place the frye...

Page 15: ...ve s DANGER All connections must be sealed with a joint compound suitable for the gas being used and all connections must be tested with a solution of soapy water before light ing any pilots Never use...

Page 16: ...PRESSURE MBAR G20 20 AUSTRIA AT II2H3B P G30 G31 50 I2E R B G20 G25 20 25 BELGIUM BE I3 G30 G31 28 30 37 G20 20 DENMARK DK II2H3B P G30 G31 30 G20 G25 20 25 II2Esi3 G30 G31 28 30 37 G20 G25 20 25 FRAN...

Page 17: ...er drain valve and fill the frypot with water and boil out solution to the bottom OIL LEVEL line at the rear of the frypot Light the fryer and perform the boil out procedures that are described in the...

Page 18: ...his appliance from one type of gas to another should only be performed by qualified licensed and authorized installation or service personnel as defined in Section 1 6 of this manual Pro Series H55 ga...

Page 19: ...the corner of the label 2 6 After the Fryers Are Positioned At the Frying Station 1 Once the fryer has been positioned at the frying station use a carpenter s level placed across the top of the frypo...

Page 20: ...BIPH255 SHOWN NOTE The appearance of your fryer may differ slightly from that shown depending upon configuration and date of manufacture Flue Top Cap Gas Valve Control Panel M2000 Computer Shown Gas V...

Page 21: ...to the bottom of the frypot 3 1 1 Setup WARNING Never operate this appliance with an empty frypot The frypot must be filled with wa ter or oil shortening before lighting the burners Failure to do so w...

Page 22: ...for a longer period When the frypot temperature reaches 180 F 82 C the unit will automatically switch to the heating mode The burners will remain lit until the frypot temperature reaches the programme...

Page 23: ...OFF switch in the OFF position also turns off the gas valve 2 Filter the oil and clean the fryers See Chapters 4 and 5 3 Place the frypot covers on the frypots 3 2 Boiling Out the Frypot To ensure tha...

Page 24: ...in handles are in their proper position before operating any switches or valves Wear all appropriate safety equipment when draining and filtering oil DANGER Allow oil to cool to 100 F 38 C before drai...

Page 25: ...fresh oil or solid shortening to the bottom OIL LEVEL line DANGER When using solid shortening pack the shortening down into the bottom of the frypot DO NOT operate the fryer with a solid block of shor...

Page 26: ...back into the fryer positioning it all the way to the back of the cabinet The filtration system is now ready for use 4 4 Operation of the Filter DANGER Draining and filtering of oil must be accomplis...

Page 27: ...hing Polishing cleans the oil by trapping solid particles in the filter pad 4 After the oil is filtered about 5 minutes close the drain valve and allow the fryer to refill Let the filter pump run 15 t...

Page 28: ...n appropriate container for transport to the disposal container Frymaster recommends the use of the McDonald s Shortening Disposal Unit MSDU NOTE If using an MSDU built before January 2004 the filter...

Page 29: ...ose or frayed wires and cords leaks foreign material in frypot or inside cabinet and any other indications that the fryer and accessories are not ready and safe for operation 5 2 2 Clean Fryer Cabinet...

Page 30: ...ER Never operate the appliance with an empty frypot The frypot must be filled with water oil or shortening before lighting the burners Failure to do so will damage the frypot and may cause a fire 5 3...

Page 31: ...esult from such scrubbing make subsequent cleanings more difficult 5 4 MONTHLY CHECKS AND SERVICE 5 4 1 Check M2000 Computer Set Point Accuracy 1 Insert a good grade thermometer or pyrometer probe int...

Page 32: ...or with plastic wrap to prevent water from entering it Spray degreaser or detergent on the blower wheel and the blower housing Allow it to soak for five minutes Rinse the wheel and housing with hot ta...

Page 33: ...nifold pressure is in accordance with the applicable table on page 2 7 and the burners display a bright orange red glow If a blue flame is observed or if there are dark spots on a burner face the air...

Page 34: ...nspection This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program Frymaster recommends that a Factory Authorized Se...

Page 35: ...tainer and cleaned daily Verify that all O rings and seals are present and in good condition Replace O rings and seals if worn or damaged Check filtration system integrity as follows Verify that filte...

Page 36: ...inues to blow find out why Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system If you ar...

Page 37: ...the drain valve s completely then press the ON OFF switch on B Gas valve is not turned on B Turn the gas valve knob to the ON position C Manual gas shut off valve closed C Verify that any in line man...

Page 38: ...play Problems Problem Probable Causes Corrective Action M2000 display is in wrong temperature scale Fahrenheit or Celsius Incorrect display option programmed M2000 computers may be programmed to displ...

Page 39: ...led computer failed transformer open high limit thermostat This indicates that the fryer is not heating It is displayed if the fryer loses its ability to heat oil It is also displayed when the oil tem...

Page 40: ...h the pump was overheated Always filter with the cooking oil shortening at or near frying temperature Allow the pump motor to cool off for about ten minutes after filtering two full frypots one after...

Page 41: ...nd that the crumb screen is used A Cooking oil is too cold for filtering A To properly filter the oil should be at or near 350 F 177 C At temperatures lower than this the oil becomes too thick to pass...

Page 42: ...Remove the controller by lifting it up and out from the hinge slots in the control panel frame 8 Re hinge the NEW controller by inserting the tabs on the bottom into the slots on the control frame pa...

Page 43: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 44: ...Shreveport Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES SE...