1-4
1.4 Setup: Main Menu
Pressing and holding the checkmark key for 10 seconds produces the setup mode, which first displays Product Setup. Turn
the controller off and follow the steps below to navigate the options.
Left Display
Right Display
Action
OFF
OFF
Start with the far LEFT controller.
Press
until the controller scrolls Info Mode,
changing to Main and then PRODUCT SETUP.
Product Setup
Blank Press
to scroll to Product Setup, Vat Setup, Tech Mode, and Exit. With the desired
selection displayed, press
.
Product Setup
Blank
Programming menu items and cooking parameters.
vat setup
Blank
Vat set up is described below in section 1.5.
Tech Mode
Blank
Tech mode is used to enable and disable Cooks and Filters options.
Exit
Exit
Press Exit/Scan button to return the controller to OFF.
1.5 Vat Setup
Vat Setup mode allows the controller to be set for language displays, vat sizes, and temperature range displays. With the
controller OFF follow the steps below. *
NOTE: Most of the system choices are only available on the far left controller.
Left Display
Right Display
Action
OFF OFF
Start with the far LEFT controller.
Press
until the controller scrolls Info Mode,
changing to Main and then PRODUCT SETUP.
Product Setup
Blank
Press
to scroll to Vat setup and press
.
Vat setup
Enter code
Enter 1656.
System
Blank
Press
.
Language English
Press
to scroll to choice and press
.
2nd language
SPANISH
Press
to scroll to choice and press
.
(This option allows another language to
be toggled easily from the front panel. (ex. Spanish as a second language.) Default
is Spanish.
Locale Non-ce
Press
to scroll to choices: CE (European Conformity standards), CE Belgium
or Non-CE (non-European standards) and press
. This option is only available on
the far left computer on multiple batteries.
Energy Gas
Press
to scroll to choices: Gas or Electric and press
.
This option is only
available on the far left computer on multiple batteries.
Type* GL30
Full
Press
to scroll choices:
Gas-
GL30 Full, GL30 Split,
Electric-
EL30-14 Full,
EL30-14 Split, EL30-17 Full and EL30-17 Split. With the current fryer vat type
displayed, press
.
SYSTEM volume
5
Sets sound level for controller. Enter level, 1-9 (1=Lowest/ 9=Loudest). Press
.
TempR format
F
Press
to scroll choices: F for Fahrenheit; C for Celsius. Press
.
Exit Melt TempR
180
º (82 ºC)
Use numbered keys to change default setting. Press
. (This is the temperature for
the fryer to exit the melt cycle.) Range is 100°F (38°C) to 200°F (93°C). Default is
180°F (82°C).
COOL MODE TEMPR
250F
(121 ºC)
Use numbered keys to change default setting. Press
. (This is the temperature
during setback or idle mode.) Default is 250°F (121°C).
COOL MODE
DEFAULT
0
Use numbered keys to change default setting. (This is the amount of minutes the
fryers sits idle before going to cool mode. Setting is disabled if set to zero.) Press
. Default is zero.
FRESH OIL
NONE
Press
to scroll choices None, JIB or Bulk. Default is none. Press
.
This
option is only available on the far left computer.
WASTE
NONE
Press
to scroll choices None or Bulk. Default is none. Press
.
This option is
only available on the far left computer.
*An expanded list of settings is available, if needed, in Tech Mode.
Summary of Contents for 3000