PT100, 230V AC, Hybrid output H1, digital input E1, screw terminal

 

284836 

 

 

 

 

Stand: 10.07.2001 

 
 

Temperature controller 

 

General Data

 

The control unit ST710-IG1BA.10 is specially designed for thermostatic controll applications. The unit works together 
with resistance sensors PT100. 
The unit offers beyond the temperature regulation a wide range of other functions.  
The output can be programmed to different functions (Parameter A1). 
 

 

SET

°C

K1

E1

 

 
 

Description

 

 

SET-key: 

The display normally shows the actual value. When the SET button is pressed , the display changes to show  
the Control Set point. 
 
 

UP-key: 

With the UP key it is possible to start a manual defrost. 
 

 

DOWN-key: 

With the DOWN key it is possible to cancel the alarm buzzer. 
 

 

First level (Set point Adjustment) 

Display of the Set Values 

 

The display normally shows the actual value of the process temperature. When the SET button is pressed , the display 
changes to show  the Control Set point (Desired temperature) 
 
 

Simultaneously press the SET button with either the UP or DOWN button to increase or decrease the Set 
point. Please release the UP or DOWN button before releasing the SET button and the new value is loaded 
into the non-volatile memory. 
 

 

Para-
meter 

Function 

Adjustable range 

Standard 
Setting 

Customer 
Setting 

S1 

Set point  

P4...P5 

0,0 °C 

 

 

SET

 

 

 

SET

 

 

Summary of Contents for KBT 02-51

Page 1: ...tions Serial products and custom made coolers Instruction Manual Mini Chest Freezer KBT 02 51 V 101207 FRYKA K ltetechnik GmbH Ohmstr 4 Phone 0049 711 310599 0 D 73730 Esslingen Fax 0049 711 310599 29...

Page 2: ...nt control with digital display setpoint control SET key and PT 100 internal temperature sensor Precise to 1 0K Control shows actual value when unit switched on To set the setpoint press the SET key a...

Page 3: ...1 F1 Refrigerant R 507 x Terminal PE N L N1 L1 L2 1 2 PE Quantity 120 gr Voltage 230 V 50 Hz Current 1 5 A Parts List M 1 Compressor TL5G V 1 Fan 4715MS W 1 Condenser FCE 12 1 180 Ft Filter Drier 10 6...

Page 4: ...the display changes to show the Control Set point UP key With the UP key it is possible to start a manual defrost DOWN key With the DOWN key it is possible to cancel the alarm buzzer First level Set p...

Page 5: ...quipped with semiconductor relays Setpoint T t symmetrical hysteresis Heating or cooling control Figure 1 T t pos Hysteresis Setpoint Cooling control Figure 2 P4 Control range limitation minimum Set p...

Page 6: ...me interval between the start of successive defrosting periods The initial start time is determined by the time of Mains on Defrosting can be initiated by interrupting the defrosting interval in advan...

Page 7: ...LED display Power Supply 230V 50Hz 60Hz current consumption max 20mA Installation Data Front panel 84 x 42 mm Panel cut out 68 x 32 mm Depth approx 85 mm incl terminals Mounting fixing strap Enclosure...

Reviews: