FrSky FSH-01 Instruction Manual Download Page 2

www.frsky-rc.com

Latitude:

Latitude:

Latitude:

Latitude:

ddmm.mmmm N/S

Installation:

Installation:

Installation:

Installation:

Use double-sided tape to install the GPS on any appropriate surface of the airframe.

Note:

Note:

Note:

Note: Up

Up

Up

Up right

right

right

right position

position

position

position is

is

is

is recommended.

recommended.

recommended.

recommended.

2.3

2.3

2.3

2.3 Variometer

Variometer

Variometer

Variometer Sensor

Sensor

Sensor

Sensor (FVAS-01)

(FVAS-01)

(FVAS-01)

(FVAS-01)

Measurement

Measurement

Measurement

Measurement Range

Range

Range

Range of

of

of

of Altitude:

Altitude:

Altitude:

Altitude:

0~9000m

Accuracy:

Accuracy:

Accuracy:

Accuracy:

1m

Installation:

Installation:

Installation:

Installation:

Use double-sided tape to install the variometer sensor on any appropriate surface of the airframe.

Note:

Note:

Note:

Note: Wind

Wind

Wind

Wind will

will

will

will affect

affect

affect

affect the

the

the

the altitude

altitude

altitude

altitude reading.

reading.

reading.

reading.

2.4

2.4

2.4

2.4 Lipo

Lipo

Lipo

Lipo Voltage

Voltage

Voltage

Voltage Sensor

Sensor

Sensor

Sensor (F

(F

(F

(FL

L

L

LVS-01)

VS-01)

VS-01)

VS-01)

FrSky lipo voltage sensor will be released quite soon, which can monitor voltage for each cell. Current FrSky voltage sensor
(FBVS-01) is suggested to be connected to telemetry receiver’s analog ports (A1 & A2).

2.5

2.5

2.5

2.5 Temperature

Temperature

Temperature

Temperature Sensor

Sensor

Sensor

Sensor (TEMS-01)

(TEMS-01)

(TEMS-01)

(TEMS-01)

Up to two temperature sensors can be used at the same time. They are commonly used to read temperatures of model
accessories, such as electric motor, ESC, glow and gas engine cylinder head, battery, muffler, voltage regulator, BEC,
tailpipe and ambient air.

Measurement

Measurement

Measurement

Measurement Range:

Range:

Range:

Range:

-20~250 degrees Celsius/ -4~482 degrees Fahrenheit

Accuracy:

Accuracy:

Accuracy:

Accuracy:

1 degree Celsius/ 1 degree Fahrenheit

Installation:

Installation:

Installation:

Installation:

Use zip ties to hold the temperature sensor tightly against the accessory that requires temperature reading.

2.6

2.6

2.6

2.6 RPM

RPM

RPM

RPM Sensor

Sensor

Sensor

Sensor (RPMS-01)

(RPMS-01)

(RPMS-01)

(RPMS-01)

RPM sensor reads RPM data by using an optical sensor.

Measurement

Measurement

Measurement

Measurement Range:

Range:

Range:

Range:

0~60000r/min

Installation:

Installation:

Installation:

Installation:

Point the RPM sensor straight up at any accessory that requires RPM reading.

Note:

Note:

Note:

Note: Indoor

Indoor

Indoor

Indoor alternating

alternating

alternating

alternating current

current

current

current lighting

lighting

lighting

lighting will

will

will

will affect

affect

affect

affect the

the

the

the RPM

RPM

RPM

RPM reading.

reading.

reading.

reading.

2.7

2.7

2.7

2.7 Triaxial

Triaxial

Triaxial

Triaxial Acceleration

Acceleration

Acceleration

Acceleration Sensor

Sensor

Sensor

Sensor (TAS-01)

(TAS-01)

(TAS-01)

(TAS-01)

Measurement

Measurement

Measurement

Measurement Range:

Range:

Range:

Range:

±8g (9.8m/s2)

Accuracy:

Accuracy:

Accuracy:

Accuracy:

0.016g

Installation:

Installation:

Installation:

Installation:

Use double-sided tape to install the triaxial acceleration sensor on any appropriate surface of the airframe.

X/Y/Z axis has been labeled on the sensor.