Starting the
diesel
e
ngine
Turn key-switch on LOFA control from
“OFF” to “RUN” position.
LOFA control
shown
with key-switch placed in “RUN” position
w
hich
illuminate
s
the
indicator lights &
activate
s
the
fuel
gauge.
The electric fuel pump for priming will operate for approx. 10 seconds.
Turn the key-switch to "OFF" & then back to "RUN" to reactivate electric
fuel pump for additional 10 sec. if extended priming is required or engine
fails to start.
After a few seconds with the key-switch
in the "RUN" position the lower indicator
lights will go off.
Engine preheating is shown by the
illuminated “PREHEAT” indicator light
and will remain on until preheating is
complete.
IMPORTANT:
DO NOT STOP
THE
ENGINE/
GENERATOR UNTIL BOTH HEATERS HAVE BEEN SHUT DOWN FIRST AND
HAVE
COMPLETED THE
IR COOL DOWN
CYCLE
AND THE FANS HAVE STOPPED.
Page
16
To stop
the
engine move key-switch to the
"OFF" position
When the“PREHEAT” indicator light goes off
move the key-switch to "START" and release
once engine starts.
If the engine starts but fails to run or it fails to