Internet
Connection
The following connection options can be configured in the "Internet" menu:
-
WLAN
-
Configured networks and available networks are listed. More networks
can be added.
-
For further information see chapter
-
Hot spot password
-
Set the hot spot password.
-
For further information see chapter
-
Advanced settings
-
Activate or deactivate "Allow Internet connection". If "Allow Internet
connection" is deactivated, functions such as the flexible electricity tar-
iff, time synchronisation or app connection to the Internet are not pos-
sible.
-
OCPP
-
Configuration of the Open Charge Point Protocol (free charging point
communication standard).
-
For further information see chapter
on page
OCPP
The charging point communication standard OCPP (Open Charge Point Protocol)
is a universal communication protocol for charging infrastructures. It enables
communication between the Wattpilot and a management system, via which, for
example, load distribution of an infrastructure or billing can be carried out. It can
be set up via a remote server provider or locally.
Activate OCPP
Activation or deactivation of OCPP.
Address
The address of the OCPP server must be provided by the provider and entered in
the OCPP menu of the app.
Phase assignment
Implement settings for how the phases of the Wattpilot are assigned compared
to a Smart Meter. This is necessary, for example, to ensure that load balancing
functions correctly.
Status
The following status indicators are available:
-
Not connected: OCPP is not activated and not connected to a management
system.
-
Started: OCPP is activated but there is no successful connection to the man-
agement system yet.
-
Connected: OCPP is activated and there is a connection to the management
system but it has not yet been accepted.
-
Connected and accepted: OCPP is activated and there is a connection to the
management system, the connection has been accepted.
Custom certificate
Possibility to enter a self-created certificate for OCPP.
Restart
After confirming the restart, the Wattpilot is restarted; the most recent settings
remain saved.
55
EN
Summary of Contents for Wattpilot Go 11 J 2.0
Page 2: ......
Page 5: ...General information 5...
Page 6: ...6...
Page 30: ...30...
Page 31: ...Installation and commissioning 31...
Page 32: ...32...
Page 42: ...42...
Page 43: ...Fronius Solar wattpilot app 43...
Page 44: ...44...
Page 57: ...Appendix 57...
Page 58: ...58...
Page 71: ...71 EN...
Page 72: ......