34
Installing the Torch Body Coupling
Safety
WARNING!
Risk of serious injuries due to mechanically moving parts and escaping com
-
pressed air.
Before beginning any work:
► Disconnect the compressed air supply line for the torch body change station from the
compressed air supply.
► Disconnect the "Gas purging 16 bar" option on the wirefeeder from the compressed air
supply.
► Ensure that all of these measures remain in place until all work is complete.
Install the torch
body coupling
NOTE!
The coupling areas between the torch body coupling and torch body must always
be free of oil, grease and dust, and be dry.
1
2
Checking the
function of the
torch body cou
-
pling
IMPORTANT!
The locking balls of the torch body coupling are intended for dry operation.
Do not lubricate the locking balls.
Actuate the torch body coupling five times using a robot signal and check whether the
torch body coupling opens and closes
If the torch body coupling opens and closes correctly, check the manual locking of a torch
body in the torch body coupling.
Flawless operation of the interchangeable coupling can only be guaranteed with a vertical
alignment facing down.
1
2
3
BY2,0201,4863
1
20Nm
2
1
42,0411,1315
2
1