The machine may only be used for jobs as defined by the “intended purpose”.

Utilisation for any other purpose, or in any other manner, shall be deemed "not
in accordance with the intended purpose". The manufacturer shall not be
liable for any damage resulting from such improper use.

Utilisation in accordance with the “intended purpose” also comprises
-

thorough reading of and compliance with all the instructions, safety in-
structions and warnings given in this manual

-

performing all stipulated inspection and servicing work

-

installation in accordance with the instruction manual

Where appropriate, the following guidelines should also be applied:
-

regulations of the power supply company for input to the grid

-

information provided by the manufacturer of the solar modules

Utilisation for
Intended Purpose
Only

For information about where the safety instructions and warning signs are
located on the machine, please refer to the section of your machine’s in-
struction manual headed “General Remarks”.

Any malfunctions which might impair machine safety must be remedied
immediately before the machine is switched on.

Your safety is at stake!

General Remarks

(continued)

Operation or storage of the machine outside the stipulated range is deemed
“not in accordance with the intended use”. The manufacturer shall not be
liable for any damage resulting therefrom.

Please refer to the technical data in your instruction manual for accurate
information about the permissible ambient conditions.

Ambient
Conditions

Qualified Staff

The servicing information provided in this instruction manual is only intended
for qualified staff. An electric shock can be fatal. Please do not carry out any
activities other than those referred to in the documentation. This also applies
even if you are suitably qualified.

All cables and other leads must be firmly attached, undamaged, properly
insulated and adequately dimensioned. Have loose connections, scorched,
damaged or under-dimensioned cables and wires repaired immediately by
an authorised specialist company.

Maintenance and repair may only be carried out by an authorised specialist
company.

There is no guarantee in the case of parts sourced from other suppliers that
these parts have been designed and manufactured to cope with the stresses
and safety requirements that will be placed on them. Use only original spare
parts (this also applies to standard parts).

Do not carry out any alterations, installations or modifications to the machine
without first getting the manufacturer’s permission.

Replace immediately any components that are not in perfect condition.

Summary of Contents for Power Control Box

Page 1: ...Fronius Power Control Box Operating instructions Data communication EN Battery Charging Systems Welding Technology Solar Electronics 42 0426 0081 EN 002 15012013...

Page 2: ......

Page 3: ...features of your new Fronius product This really is the best way to get the most out of all the advantages that your machine has to offer Please also take special note of the safety rules and observe...

Page 4: ......

Page 5: ...ll the safety instructions and warning signs on the machine itself must be kept in a legible condition must not be damaged must not be removed must not be covered pasted or painted over General Remark...

Page 6: ...of the machine outside the stipulated range is deemed not in accordance with the intended use The manufacturer shall not be liable for any damage resulting therefrom Please refer to the technical dat...

Page 7: ...n class B satisfy the emissions criteria for residential and industrial areas This also applies to residential areas in which power is supplied from the public low voltage grid EMC device classificati...

Page 8: ...quipment and its implementation as national law electrical equipment that has reached the end of its life must be collected separately and returned to an approved recycling facility Any device that yo...

Page 9: ...lays 9 Connecting the Fronius Power Control Box to a ripple control signal receiver with 2 relays 9 Connecting the Fronius Power Control Box to a ripple control signal receiver with 3 relays 10 Integr...

Page 10: ...t conditions and at the maximum possible output power of the inverter 2 60 power limitation at 60 energy is fed into the grid in optimum light conditions and at 60 of the maximum possible output power...

Page 11: ...nt versions are required on the inverter to operate the Fronius Power Control Box Electronic component Inverter Version IG BRAIN Fronius IG Plus V 4 28 20 Fronius IG Plus V Fronius CL PINCI Fronius IG...

Page 12: ...o 3 4 12VDC Class 2 Input only I 1 2 3 4 5 6 7 No Function 1 Supply LED lights up green there is a sufficient power supply through the Fronius Solar Net does not light up there is an insufficient or n...

Page 13: ...ns adapter to provide an external power supply to the Fronius Power Control Box The supply LED 1 lights up green if there is a sufficient power supply 6 Fronius Solar Net IN connection Fronius Solar N...

Page 14: ...ntrol Box Choice of location Note the following criteria when choosing the location Only install on a firm surface The ambient temperature must not fall below 0 C or exceed 55 C The IP 20 degree of pr...

Page 15: ...7 Attaching the Fronius Power Control Box to the wall bra cket 1 3 2 1...

Page 16: ...wer Control Box to a ripple control signal receiver CAUTION Risk of serious injury from electric shock and risk of damage to the Fronius Power Control Box The ripple control signal receiver contacts m...

Page 17: ...t exceed 10 m 4 relay mode connection diagram Connecting the Fronius Power Control Box to a ripple control signal receiver with 2 relays 1 Connect the ripple control signal receiver and Fronius Power...

Page 18: ...ver Fronius Power Control Box 60 30 0 1 2 3 1 2 3 4 5 6 7 8 9 10 11 12 GND GND 1 2 3 4 I If none of the relays are actuated there is no power limitation Important Lines are not monitored in 3 relay mo...

Page 19: ...not light up an external power supply is required for the Fronius Power Control Box Connecting the external power supply to the Fronius Power Control Box Mode 1 2 3 4 5 6 7 8 9 10 11 12 GND GND 1 2 I...

Page 20: ...ted to the termi nals 4 relay mode factory setting Depending on the limit set by the ripple control signal receiver 100 60 30 or 0 of the maximum possible output power is fed into the grid 0 1 4 9 Res...

Page 21: ...ronius Power Control Box 1 Use a screwdriver on the operating mode adjusting dial to set the required mode for the Fronius Power Control Box Important A value between 1 and 9 must be set for the Froni...

Page 22: ...key is enabled Display mode Now energy currently fed into the grid with Enter key enabled Inverter dis play 1 In the display mode Now call up the energy currently being fed into the grid The Enter key...

Page 23: ...hat the power reduction has been in effect is displayed in H MM In the area for the display unit H and LIM are displayed alternately 4 Press the Menu key to switch back to the current power value Inve...

Page 24: ...able s from ripple control signal recei ver to Fronius Power Control Box or cable s not plugged in Remedy Check cables and connections Cause The ripple control signal receiver is faulty only in 3 rela...

Page 25: ...7 Technical data Fronius Power Control Box Supply voltage 12 V DC Energy consumption 1 3 W Degree of protection IP 20 Dimensions l x w x h 197 x 110 x 57 mm Interfaces RS 485 RJ 45 IN RS 485 RJ 45 OUT...

Page 26: ......

Page 27: ......

Page 28: ...http www fronius com USA A Fronius Worldwide www fronius com addresses Fronius USA LLC Solar Electronics Division 6797 Fronius Drive Portage IN 46368 E Mail pv us fronius com http www fronius usa com...

Reviews: