Before commissioning
Mains connec-
tion
The rating plate, which is located on the housing, contains information about the
permitted mains voltage. The device is designed for this mains voltage only. For
details on the required fuse protection for the mains lead, see the
section on page
. If there is no mains cable or mains plug on your version of
the appliance, fit one that conforms to national standards.
CAUTION!
Danger due to insufficiently dimensioned electrical installations.
This can result in serious damage to property.
▶
The mains lead and its fuse must be dimensioned to suit the local power sup-
ply.
▶
Read the technical data on the rating plate.
Generator-
powered opera-
tion
The charger is completely generator-compatible, provided the maximum appar-
ent power delivered by the generator is at least 2 kVA.
This also applies if the generator in question is an inverter.
NOTE!
The voltage delivered by the generator must never exceed the upper or lower
limits of the mains voltage tolerance range.
Details on the mains voltage tolerance can be found in the
section
on page
.
Setup regula-
tions
WARNING!
Danger from machines toppling over or falling.
This can result in serious personal injury and damage to property.
▶
Set up the device securely on an even, solid surface.
▶
Check all screw connections are tightly fastened after installation.
The device is tested to IP40 protection, meaning:
-
Protection against penetration by solid foreign bodies with diameters > 1.0
mm (0.04 in.)
-
Protection against spraywater at any angle up to 60° to the vertical when fan
is not running.
Dust
Ensure that metallic dust is not sucked into the system by the fan, when carrying
out grinding for example.
Outdoor operation
The device can be set up and operated outdoors in accordance with IP40 degree
of protection. Avoid direct wetting (e.g. from rain).
73
EN
Summary of Contents for AccuPocket 150/400 TIG
Page 2: ......
Page 6: ...6...
Page 7: ...Safety rules 7...
Page 8: ...8...
Page 24: ...24...
Page 25: ...Power source 25...
Page 26: ...26...
Page 28: ...Application areas MMA welding TIG welding 28...
Page 56: ...Every 2 months Clean the air filter if fitted 1 56...
Page 69: ...Charger 69...
Page 70: ...70...
Page 84: ...84...
Page 85: ...85 EN...
Page 86: ...86...
Page 87: ...87 EN...