Technical data
Environmental
conditions
Transport, storage or operation of the device outside the stipulated range will be
deemed improper. The manufacturer shall not be held liable for any damage
arising from such usage.
Ambient air temperature range:
-
During operation: -10 °C to + 40 °C (14 °F to 104 °F)
-
During transport: -20 °C to +55 °C (-4 °F to 131 °F)
-
Recommended temperature range during charging:
+ 4 °C to + 40 °C (+ 39.2 °F to + 104 °F)
-
Recommended temperature range during storage:
0 °C to + 20 °C (+ 32 °F to + 68 °F)
When placing in storage, the state of charge should ideally be at 50 - 80%
(corresponds to approx. 2 to 3 bars on the charging status indication).
Relative humidity:
-
Up to 50% at 40 °C (104 °F)
-
Up to 90 % at 20 °C (68 °F)
The surrounding air must be free from dust, acids, corrosive gases or substances,
etc.
Can be used at altitudes up to 2000 m (6561 ft.)
80
Summary of Contents for AccuPocket 150/400 TIG
Page 2: ......
Page 6: ...6...
Page 7: ...Safety rules 7...
Page 8: ...8...
Page 24: ...24...
Page 25: ...Power source 25...
Page 26: ...26...
Page 28: ...Application areas MMA welding TIG welding 28...
Page 56: ...Every 2 months Clean the air filter if fitted 1 56...
Page 69: ...Charger 69...
Page 70: ...70...
Page 84: ...84...
Page 85: ...85 EN...
Page 86: ...86...
Page 87: ...87 EN...