53
EN-US
Output frequency range
Setups: 50Hz, 60Hz
Setup: HI1
48.0 - 50.5 Hz / 59.3 - 60.5 Hz
- / 57.0 - 63.0 Hz
Setting range for grid frequency
45.0 - 55.0 Hz / 50.0 - 65.0 Hz
Frequency limit accuracy
0.05 Hz
Frequency clearing times setting range
0.016 - 600 s
Total harmonic distortion
< 5 %
< 2.5 %
Power factor (cos phi)
0.85 - 1 ind./cap..
1)
0 - 1 ind./cap..
1)
General data
Maximum efficiency
97.9 %
97.9 %
CEC efficiency
at 208 V
at 220 V
at 240 V
97.0 %
97.0 %
97.0 %
97.0 %
97.0 %
97.0 %
97.0 %
97.0 %
97.0 %
Night self-consumption
at 208 V
at 220 V
at 240 V
0.4 W
0.6 W
0.6 W
Self-consumption during operation
10 W
Cooling
Forced-air ventilation
Degree of protection
NEMA4X
Dimensions l x h x w
24.7/16.9/8.1 inch
628/428/205 mm
28.5/20.1/8.9 inch
725/510/225 mm
Weight
42.0 lbs. (21.45 kg)
82.5 lbs. (37.4 kg)
Shipping dimensions l x h x w
30.1/21.7/11.4 inch
770/550/290 mm
31.1/22.6/13.4 in.
790/575/340 mm
Shipping weight
57.6 lbs. (26.11 kg)
90.2 lbs. (40.9 kg)
Permissible ambient temperature
(at 95% rel. humidity)
-40 °F - +131 °F
(-40 °C - +55°C)
-40 °F - +140 °F
(-40 °C - +60°C)
Permissible storage temperature
(with 95% rel. humidity)
-40 °F - +158 °F (-40 °C - +70°C)
Protection devices
Insulation monitoring
Integrated
Stand alone operation protection
Integrated
Reverse polarity protection
Integrated
Arc Detector / Interrupter
Integrated
Overtemperature
Operating point offset / active cooling
1)
Ind. = inductive cap. = capacitive
Fronius Primo
7.6-1 208-240
8.2-1 208-240
10.0-1 208-240