PAGE 10 OF 26
0118 IH-7184
10
P329 M_HA mane.fm
6
OPERATION
6.1 Installation
Do not expose power tools to rain or wet conditions!
The batteries are supplied partially charged.
Before the first use, the battery must be completely charged.
See separate operating instruction of the battery charger.
Never charge a damaged battery. Replace by a new one immediately.
Do not open batteries and store them only in dry and frost-proof rooms.
Do not store the battery pack together with metal objects (short circuit risk).
The maximum ambient temperature is 50°C.
Keep dry at all times.
Inserting the battery
• Insert the battery from top to bottom into the tool
until both unlatching push buttons are engaged.
When inserting the battery the LED - indication
shortly lights green.
Removing the empty battery
If the red LED starts lighting while a tensioning or
welding procedure, the capacity of the battery is
exhausted. All electric functions of the tool are
blocked.
The battery must be recharged.
• Push the unlatching push buttons at both sides of the battery.
• Pull the battery out of the tool.
Displaying of the status of the battery charge
By pressing a button the status of the battery can be
shown in four steps.
If four lamps are lighting the battery is full.
If only one lamp is lighting shortly the battery has to be
charged.
Push here