ALARMS AND ERRORS
THE CARRIAGE DOES NOT STOP AT THE LOWER OR UPPER LIMIT STOP MICROSWITCH
The arrised problem
Possible remidies
- Limit switches and not connected properly
-
Check the wiring
- Limit switch malfunctioning
- Replace the limit switch
- Limit stop cam incorrectly positioned
- Check for the position of the cams by
adjusting the respective adjuster screws
THE PHOTO ELECTRIC CELL IS NOT WORKING
The arrised problem
Possible remidies
- Photo electric cell is not detecting the pallet
-
Check if the machine is not in program 6
- Check parameter 0 “pallet overlap”
- Check the background of the machine (To
much white gives problems
- Is the colour of the stretchfilm
corresponding with the required photo cell
WHEN THE FILM TENSION VALUE IS INCREASED OR DIMINISHED, TENSION DOES NOT
CHANGE
The arrised problem
Possible remidies
- clutch not connected properly
- Check the connection
- clutch not working
- Replace the clutch
Option kit 16.8240